Summary of SmartSwitch 9000

  • Page 1

    Smartswitch 9000 9f241-12 user’s guide 9031203-01.

  • Page 3: Notice

    I notice notice cabletron systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult cabletron systems to determine whether any such changes have been made. The hardware, firmware, or soft...

  • Page 4: Fcc Notice

    Notice ii fcc notice this device complies with part 15 of the fcc rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Not...

  • Page 5

    Iii notice declaration of conformity addendum application of council directive(s): 89/336/eec 73/23/eec manufacturer’s name: cabletron systems, inc. Manufacturer’s address: 35 industrial way po box 5005 rochester, nh 03867 european representative name: mr. J. Solari european representative address: ...

  • Page 6

    Notice iv.

  • Page 7: Contents

    V contents chapter 1 introduction features........................................................................................................................... 1-1 related manuals............................................................................................................ 1-4 ge...

  • Page 8

    Contents vi.

  • Page 9: Chapter 1

    1-1 chapter 1 introduction the 9f241-12 microlan module is a dual attached concentrator module for the smartswitch 9000 (see figure 1-1). The 9f241-12 provides twelve multimode fiber master ports allowing the connection of single or dual attached stations. The 9f241-12 is ansi fddi-compliant with sm...

  • Page 10

    Introduction 1-2 management information base (mib) support the 9f241-12 provides mib support, including the following: • ietf fddi mib • ietf mib ii • a host of cabletron enterprise mibs. Lanview leds the 9f241-12 uses lanview, the cabletron systems built-in visual diagnostic and status monitoring s...

  • Page 11

    1-3 introduction figure 1-1. The 9f241-12 module 1 5 m 1 m 2 m 3 m 4 m 5 m 6 m 9 m 10 9 4 8 12 m 7 m 8 m 11 m 12 smb cpu fnb 9f241-12 fddi.

  • Page 12: Related Manuals

    Introduction 1-4 related manuals the manuals listed below should be used to supplement the procedures and technical data contained in this manual. Smartswitch 9000 installation guide smartswitch 9000 operations guide smartswitch 9000 9c300-1 environmental module user’s guide smartswitch 9000 9c214-1...

  • Page 13: Chapter 2

    2-1 chapter 2 installing the microlan module this section describes how to unpack, configure and install the module into the smartswitch 9000 chassis. Unpacking the module 1. Carefully remove the module from the shipping box. (save the box and packing materials in the event the module must be reship...

  • Page 14

    Installing the microlan module 2-2 figure 2-1. User-accessible components smb-1 prom i960 processor flash simm socket boot prom dip switch.

  • Page 15

    2-3 installing the microlan module setting the module card dip switch an eight-position dip switch is located on the module card, as shown in figure 2-1 and figure 2-2. The functions of the switches are listed in table 2-1. Figure 2-2. Location of module dip switch 1 2 3 4 5 6 7 8.

  • Page 16

    Installing the microlan module 2-4 see the cautions at the end of this table. Table 2-1. Function of dip switch switch function description 8 clear password 1 when toggled, this switch clears user-entered passwords stored in nvram, and restores the default passwords. Once reset you can use the defau...

  • Page 17: Chassis

    2-5 installing the microlan module installing the module into the smartswitch 9000 chassis smartswitch 9000 microlan modules can be installed in any of the 14 slots that are available. To install, follow the steps below: 1. Switch off the power supplies and remove all power from the smartswitch 9000...

  • Page 18

    Installing the microlan module 2-6 figure 2-3. Installing the smartswitch 9000 module metal back-panel module guides module jack for esd wrist strap plastic tab warning: ensure that the circuit card is between the card guides. Lock down the top and bottom plastic tabs at the same time, applying even...

  • Page 19: The Reset Switch

    2-7 installing the microlan module the reset switch the reset switch is located on the front panel, under the top plastic tab, as shown in figure 2-4. It serves two functions: • pressing the reset switch twice within three seconds causes the processor (i960) to reset. • pressing and holding the swit...

  • Page 20

    Installing the microlan module 2-8.

  • Page 21: Chapter 3

    3-1 chapter 3 operation the 9f241-12 module, as shown in figure 3-1, provides concentrator ports that connect directly to the fnb bus. Each port can connect to either ring (fnb-1 or fnb-2). This is software configurable via local or remote management. Figure 3-1. Block diagram flexible network bus (...

  • Page 22: System Management Buses

    Operation 3-2 system management buses there are two management channels within the smartswitch 9000 system: the smb-1 and the smb-10. These buses provide out-of-band management and inter- module management communication. Smb-1 bus the smb-1 is a 1 mbps management bus located within the smartswitch 9...

  • Page 23: Dc/dc Converter

    3-3 operation dc/dc converter the dc/dc converter converts the 48 vdc on the system power bus to the necessary operating voltages for its host network services module. The diagnostic controller monitors and controls the operation of the dc/dc converter. Fnb interface smartswitch 9000 modules are des...

  • Page 24

    Operation 3-4.

  • Page 25: Chapter 4

    4-1 chapter 4 lanview leds the front panel lanview leds indicate the status of the module and may be used as an aid in troubleshooting. Shown in figure 4-1 is the lanview leds of the concentrator modules. Figure 4-1. The lanview leds 1 5 m 1 9 4 8 12 smb cpu fnb 9f241-12 fddi system status and cpu f...

  • Page 26

    Lanview leds 4-2 the functions of the system management bus (smb) and the cpu leds are listed in table 4-1. The functions of the fnb receive leds are listed in table 4-2. The functions of the fnb transmit leds are listed in table 4-2. Table 4-1. Smb and cpu leds led color state description green fun...

  • Page 27

    4-3 lanview leds there is one fddi port led for each master port. The functions of the fddi port leds are listed in table 4-4. Table 4-4. Fddi status leds led color state green link, activity, port enabled yellow link, no activity, port enabled red no link, port disabled red (flashing) link, port di...

  • Page 28

    Lanview leds 4-4.

  • Page 29: Chapter 5

    5-1 chapter 5 specifications safety this equipment meets the following safety requirements: • ul 1950 • csa c22.2 no. 950 • en 60950 • iec 950 • emi requirements of fcc part 15 class a • en 55022 class a • vcci class i • emc the following requirements: en 50082-1 iec 801-2 esd iec 801-3 radiated sus...

  • Page 30

    Specifications 5-2 physical dimensions: 35.0 d x 44.0 h x 3.0 w centimeters (13.8 d x 17.4 h x 1.2 w inches) weight: unit: 1360.7 gr. (3 lb) shipping: 1814.4 gr. (4 lb) link distance up to two kilometers on multimode fiber-optic cable as specified by ansi mmf-pmd, using sc connectors specified by an...