CalAmp Fusion User Manual - page 14
Fusion Multi-Network LTE Router PN 001-0000-602 Rev. B
| Page 8
1.7 LEDS
Table 8 Status LEDs
Indicator
Off
Solid
Green
Flashing
Green
Solid Amber
Flashing
Amber
Solid Red
Flashing Red
PWR
No power
Running
–
Hardware
power-up
sequence
Firmware
boot
sequence /
Power-down
timer
activated
(1)
Power
supply
fault
–
STAT
No power
Status:
Normal
–
Status:
Warning
Status:
Factory
Defaults
Status:
Fault
–
GPS
–
Position Fix
Acquired
1 PPS
Activity
Failed to
Acquire
Satellites
Acquiring
Satellites
Fault
–
WiFi
(2)
(Client)
I/F Disabled
Connected
Rx/Tx
Activity
–
–
Fault
–
WiFi
(2)
(AP)
I/F Disabled
Ready
Rx/Tx
Activity
–
–
Fault
–
WWAN0/
WWAN1
I/F Disabled,
Idle, or
Bypassed
Connected
Rx/Tx
Activity
Failed to
Connect
Connecting
Fault
–
ETH
Link/Act
No link
Link OK
Activity
–
–
–
–
ETH
Speed
10 Mbps
–
–
100 Mbps
–
–
–
(1)
The “Power-Down Timer Activated” is a transient condition that exists when the “ignition” input is OFF and the
“power-management – shutdown when ignition is off” feature is activated. It means that the unit is about to shut
down and this will occur when the timer has expired.
(2)
WiFi Client has priority over the WiFi AP function. This implies that WiFi Client has ownership of the LED when it is