Eberspächer EasyStart Timer Installation Instructions Manual - 11.3: 60
Other manuals for EasyStart Timer:
Operating Instructions Manual
of
20
14 | VEhICLE hEATERs – TEChnICAL DOCuMEnTATIOn
3 sTARTup / COnFIguRATIOn
FOR AuTOMATIC OpERATIng TIME CALCuLA-
TIOn, EnTER ThE OpERATIng TIME – ITEM
11.3:
Default: 60 minutes
use the
or
button to select Item
11.3: and confirm by pressing the
button.
use the
or
button to set the operat-
ing time.
setting range: 10 – 60 minutes.
11.3: 60
SERVICE
press the
button to confirm the setting.
please nOte!
press the
button to exit the Workshop
menu.
If the vehicle is only used for short trips,
consult the customer and reduce the maxi-
mum operating time.
Carry out a function test after configuration.