12
RECHARGING THE SOFTENER
This feature may be used to assure an adequate supply
of softened water at times of unusually high water use.
For example, if you have guests and the “Water avail-
able” screen (See Page 16) is at or below 50%, you
could deplete softened water capacity before the next
automatic recharge. Initiating a manual recharge will
restore 100% softened water capacity after complete.
1. From any of the rolling status screens, press the
SELECT (
) button to display the Main menu.
FIG. 29
2. Make sure Recharge is highlighted (See Figure 28).
3. Press the SELECT (
) button to display the
Recharge menu (See Figure 29).
FIG. 28
4. If the desired option already has a black dot next to it
(See Figure 29), go to Step 5. Otherwise, press the
DOWN (
) or UP () buttons to scroll to the desired
option, then press SELECT (
) to choose it.
Automatic cancels a manually scheduled recharge
(if it has not already begun) and lets the electronic
control determine when to recharge next.
Recharge now begins a recharge immediately
after the SELECT (
) button is pushed again in Step
5.
Schedule sets a recharge to begin at the preset
recharge time (set according to the instructions on
Page 13).
5. Press the SELECT (
) button. If Recharge now is
selected, the display immediately goes to the
Recharge status screen (See Figure 30). If
Automatic or Schedule are selected, the display
goes back to the Main menu (Figure 28).
SETTING THE CURRENT TIME
When the softener’s electronic control is first powered
up, a “wizard” screen prompts you to set the current
time (See Page 8). To change the time at a later date,
such as after a long power loss:
1. From any of the rolling status screens, press the
SELECT (
) button to display the Main menu.
2. Press the DOWN (
) button to scroll through the
menu options until Basic settings is highlighted
(See Figure 31).
3. Press the SELECT (
) button to display the Basic
settings menu (See Figure 32).
FIG. 31
FIG. 32
4. Make sure Current time is highlighted.
5. Press the SELECT (
) button to display the Current
time screen (See Figure 33).
6. Press the UP (
) or DOWN () buttons to change
the time. Hold the button down to rapidly advance.
Be sure that AM or PM is correct (unless softener is
set for a 24-hour clock).
7. Press the SELECT (
) button. The display will go
back to the Basic settings menu (Figure 32).
8. Press the LEFT (
) button twice to return to the
rolling status screens.
FIG. 33
FIG. 30
6. Press the LEFT (
) button (twice from the Recharge
status screen) to return to the rolling status screens.
ECOWATER
S Y S T E M S
Conditioner Operation