EcoWater ECR 3500R20 Owner's Manual - page 27
27
RECHARGING THE SOFTENER
This feature may be used to assure an adequate supply
of softened water at times of unusually high water use.
For example, if you have guests and the “Capacity
remaining” line on the softener status screen is at or
below 50%, you could deplete softened water capacity
before the next automatic recharge. Initiating a manual
recharge will restore 100% softened water capacity
after complete.
1. Press the remote’s LEFT (
) or RIGHT () buttons
to manually advance to the Softener status screen
(See Figure 108).
4. Press the SELECT (
) button to display the
Recharge menu (See Figure 110).
5. The currently selected option has a black dot next to
it. Press the DOWN (
) or UP () buttons to scroll
to the desired option, then press SELECT (
) to
choose it.
Automatic cancels a manually scheduled recharge
(if it has not already begun) and lets the electronic
control determine when to recharge next.
Recharge now begins a recharge after the
SELECT (
) button is pushed again in Step 6.*
Schedule sets a recharge to begin at the preset
recharge time (set according to the instructions at
right).
FIG. 110
FIG. 109
FIG. 111
FIG. 112
SETTING SOFTENER RECHARGE TIME
When the softener’s electronic control is first powered
up, the default time for starting an automatic recharge is
2:00 a.m. This is a good time in most households
because water is not being used.
To change the softener’s recharge time using the
remote:
1. Press the remote’s LEFT (
) or RIGHT () buttons
to manually advance to the Softener status screen
(See Figure 108).
2. Press the remote’s SELECT (
) button to display the
device menu (See Figure 109).
3. Press the DOWN (
) button to scroll through the
menu options until Recharge time is highlighted in a
box (See Figure 111).
4. Press the SELECT (
) button to display the
Recharge time screen (See Figure 112).
FIG. 108
2. Press the remote’s SELECT (
) button to display the
device menu (See Figure 109).
3. If necessary, press the DOWN (
) button to scroll
through the menu options until Recharge is highlight-
ed in a box (See Figure 109).
6. Press the SELECT (
) button. The display will go
back to the softener menu (Figure 109).
7. Press the LEFT (
) button to exit this menu, or wait
30 seconds for it to exit automatically.
* The softener may not respond instantly to the remote’s command. Because of the way information is distributed in the
HydroLink™ network, it may take a few seconds (or even minutes if multiple AC powered devices are in the network).
ECOWATER
S Y S T E M S
Remote Operation
5. Press the UP (
) or DOWN () buttons to change
the recharge time in 1 hour increments. Hold the
button down to rapidly advance. Be sure that AM or
PM is correct (unless softener is set for a 24-hour
clock).
6. Press the SELECT (
) button. The display will go
back to the softener menu (Figure 111).
7. Press the LEFT (
) button to exit this menu, or wait
30 seconds for it to exit automatically.
continued