Ferimex E-4000 User Manual - page 5
Connecting to the mains supply
The device is power supplied with stabilised directed voltage of 5V. We recommend
using an uninterruptible power supply (UPS).
First configuration
First configuration is usually done using a serial null-modem cable connected to the
serial port of a computer. The default ip address of first ethernet port (eth0) is
192.168.10.60, so you could also log in via ssh. Upon login the device will prompt for
a login and a password:
manager login: admin
password: admin
If you want to change the ip address, issue the following commands:
manager$ set eth0 ip 10.10.10.10/24
ipaddr: 10.10.10.10
netmask: 255.255.255.0
manager$ reload net
That sets the ip address and applies the settings. If the networing parameters are set
up correctly, you can access and configure the traffic manager via ssh on the new
address. All the configuration is done in command line.
Commands reference
help command
The help command shows available commands and their parameter syntax. With
argument, it shows more detailed description of the subsystem. Without arguments,
it gives this short overview of all the available commands:
show (if|wlan|eth|br)[:] # displays summary of all interfaces in given class
set|show
set|show cl[ass]|snmp|dl|download|redir|frw|firewall|cfg|config|system
show ver[sion]
route add|del|show|print|flush
reload [net|br|[work]|wlan|cfg|route|ac[cess]|class|frw|redir|snmp|sys-
tem]
restart
passwd # changes current user's password
help [ip|wlan|class|snmp|route|download|config]
How to interpret the help text:
- the pipe symbol „|“ represents choice of alternatives
6
TRAFFIC MANAGER E-4000