Ganz ZC-PT336N-IR User manual - page 12
C-6. Connect the cables referring to the page 8. (FIG.14)
Quick Operating Keys
The IR Camera supports Pelco D/P Protocols
The default setting of the IR Camera is Pelco D/P(Auto Detection) with 2400bps (Baud rate).
[PELCO D/P PROTOCOLS]
The comprehensive feature set of the camera is available from Pelco Compatible controllers via
quick operation keys as defined below. 1 ˜ 64 + preset and 100 ˜ 200 + preset are used for
normal user presets. Presets 65 ˜ 99 + are reserved for special functions. For Example, to enter
OSD MENU, press the button 95 + Preset.
Number
Note
Function
1 ˜ 64, 100 ˜ 200 + PRESET
Preset
Executing Preset 1 ˜ 64, 100 ˜ 200
65 + PRESET
Preset Status
Display Preset Status
66 + PRESET
Auto Scan
Executing Auto Scan
70 + PRESET
VIB CORR
Selectable On / Off in picture Stabilization Function
71 ˜ 78 + PRESET
Group Tour
Executing Group Tour #1 ˜ #8
81 ˜ 88 + PRESET
Pattern
Executing Pattern #1 ˜ #8
91 + PRESET
Zero Position
Searching Pan / Tilt Zero Position
92 + PRESET
Freeze
Select Freeze image when camera is working
93 + PRESET
BLC
Selectable On / Off BLC function
94 + PRESET
Day/Night
Selectable Day / Night / Auto Mode
95 + PRESET
OSD
Entering OSD Main Menu
96 + PRESET
Focus Adjust
Focus adjust
97 + PRESET
Alarm
Selectable Enable / Disable all alarms
98 + PRESET
AUX1
Selectable On / Off Aux1
99 + PRESET
AUX2
Selectable On / Off Aux2
Number
Function
1 ˜ 64, 100 ˜ 200 + PRESET
Sub menu cursor moves up / down
65 + PRESET
Enter to the sub menu or status change or decrement
66 + PRESET
Using for enter key when user select YES or NO
70 + PRESET
Using for function changing keys when set coordinate