Jandy AE-Ti Installation And Operation Manual - page 18
Page 16
4.4 Pump
Connection
(Auto-Heat
Feature)
(Residential only) When connecting the time
clock override parallel circuit, proper phasing must
be maintained. Use 12 AWG wire. Follow the wiring
diagram on the service access panel of your heat pump,
referring to the auto-contactor section (see Figures 10
and ll on pages 13 and 14). The use of four different
color wires will help in maintaining the proper phasing
to and from the pool pump time clock.
4.5
Optional Remote Controls
Electrical wiring must be in accordance with
the latest edition of the NEC (NFPA 70) in the United
States and CEC (CSA 22.1) in Canada, unless local
code requirements indicate otherwise. To connect
remote control equipment to the heat pump, perform the
following steps:
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the 5 screws that attach the service/access
panel to the heat pump unit (see Figure 12 on
page 15). This will allow you to access the wires
from the AE-Ti control panel for the remote
control installation (see Figure 13).
3. Run the wires from the pool/spa control system
into the conduit connection labeled “Low Voltage
Connection”, located on the lower right hand side
of the heat pump (see Figures 12 and 14).
4. Strip approximately 1/4” of insulation from the
heat pump remote control wires (black and white,
see Figure 14).
5. Using wire nuts, connect the wiring from the
pool/spa control system to the heat pump remote
control wires.
6. Restore power to the heat pump and the pool/spa
control system.
NOTE For AquaSwitch® or three wire remote controls,
connect the HIGH and COMMON wires to the
heat pump remote control wires.
4.5.1
Connection to an AquaLink RS
Control System
1. Install a fi xed resistor, with a value of 2.2K Ohms,
in the solar sensor terminals #3 and #4 of the
green, 10-pin terminal bar of the AquaLink RS
Power Center (see Figure 15).
Figure 13. AE-Ti Control Panel, Interior View
Black and White Wires for
Remote Control
Run Wires from
Pool/Spa System
through Low
Voltage Conduit.
Figure 14. AE-Ti Control Panel - Remote Control
Wiring