Figure 16. Main Control Panel
5.2.3
Pool Mode - (Optional Auto Heat)
If connected, the Auto-Heat mode allows the
heat pump to monitor the temperature of the water 24
hours a day by turning the pool pump on and sampling
the water temperature. When the water temperature
drops below the programmed temperature set point, the
control will start the heat pump.
To operate in pool mode with the Heat Auto-
Run feature, press
POOL
, then press
Time/Auto
. The
LED indicators on both buttons will light and the unit
will display
POOL TEMPERATURE SET-POINT =
XX°
for 5 seconds. Change the temperature set point
by pressing the
Up
or
Down
buttons until the desired
set point is displayed. After 5 seconds of inactivity the
unit will display
POOL
→
AUTO-HEAT
along with the
current pool temperature and the delay time remaining
until the heat pump starts.
5.2.4
Spa Mode - (Optional Auto Heat)
If connected, the spa mode automatically enables
the Auto-Run feature. Press
SPA
to enable spa mode.
The LED indicator will light and the unit will display
SPA TEMPERATURE SET-POINT = XX°
for 5
seconds. Change the temperature set point by pressing
the
Up
or
Down
buttons until the desired set point is
displayed. After 5 seconds of inactivity the display will
read
SPA AUTO-HEAT
along with the current spa
temperature and the delay time left until the heat pump
starts. Additionally, the new set point will be stored in
memory. The default factory setting for Spa temperature
is 104 degrees.
5.2.5 Keypad
Lockout
To lockout the keypad
in any operating mode
,
press and hold the
POOL
,
SPA
, and
Heat/Cool
buttons
for 6 seconds. All control buttons will be disabled and
the control will operate in the mode it was in when the
keypad lockout occurred. If any button is pressed when
the keypad is in lockout mode, the unit will display
SYSTEM LOCKED
for 5 seconds. To unlock the
keypad, press and hold the
POOL
,
SPA
, and
Heat/Cool
buttons for 6 seconds. The unit will display
SYSTEM
UNLOCKED
.
5.2.6 Feature
Lockout
To lockout all features except the
On/Off, POOL
and
SPA
buttons
in any operating mode
, press and
hold the
Time/Auto, Heat/Cool
and
Down
buttons
for 6 seconds. All control buttons except the
On/Off,
POOL
and
SPA
will be disabled. If any button is
pressed when the keypad is in feature lockout mode, the
unit will display
FEATURE LOCKED
for 5 seconds.
To unlock the keypad, press and hold the
Time/Auto,
Heat/Cool
and
Down
buttons for 6 seconds. The unit
will display
FEATURE UNLOCKED
.