Initial Start-up Precautions
ATTENTION
After starting the AE-Ti heat pump, please
note that there is a 5 minute delay before the
compressor begins operation. The heat pump
display will show the remaining delay time in
minutes.
Be sure that there is water in the pool and that the
surface level is above the skimmer or other inlet of the
pool’s filter system.
With any new pool or spa installation, operate
the filter pump with the heat pump off long enough
to completely clean the water. This will remove any
installation residue from the water. Clean the filter at
the end of this operation before starting the heat pump.
When raising the temperature of a cold pool, program
the time clock to run the pump continuously. This lets
the filter system and heat pump operate continuously
until the water reaches the temperature setting on the
temperature control. When that happens, the heat pump
will automatically shut off, but the filter pump will keep
running.
5.2
Operating the Controller
Your new AE-Ti heat pump is controlled by an
advanced microprocessor based controller that provides
a sophisticated yet simple interface to operate your heat
pump for maximum efficiency and enjoyment of your
pool. To locate the control buttons, see Figure 16.
5.2.1 Off/On
Button
When the control panel is turned off, the screen
displays
CONTROL IS OFF
and the
Off/On
LED
indicator is not lit. Press
Off/On
to turn on the control
panel. The LED will light and the display will read
PLEASE SELECT POOL OR SPA
.
5.2.2
Pool Mode - (Normal Heat)
To enable the pool mode, press
POOL
. The LED
indicator will light and the unit will display
POOL
TEMPERATURE SET-POINT = XX°
for 5 seconds.
NOTE
XX
represents the current temperature setting
on the control. The default setting for pool
temperature is 82°F.
After 5 seconds the unit will display
POOL
→
HEAT
and the current pool temperature
.
You can
change the temperature set point by pressing the
Up
or
Down button
. The display will change back to
show
POOL TEMPERATURE SET-POINT = XX°.
Repeatedly press the Up or Down
button until you
reach the desired temperature set point. After 5 seconds
of inactivity, the new set point is stored in memory.
When the water temperature falls to 1 degree below
the temperature setting
and
after a 5- minute delay, the
control will start the heat pump.
Section 5. Operation
CAUTION
Keep all objects off the top of the heat pump.
Blocking air fl ow could damage the unit and
may void the warranty.
ATTENTION
Ne posez aucun objet sur le dessus de
l’appareil. Il pourrait empêcher la circulation de
l’air, ce qui risquerait d’endommager l’appareil
et d’annuler la garantie.
PRECAUCIÓN
Mantenga todos los objetos fuera de la parte
superior de la bomba de calor. La obstrucción
del fl ujo de aire podría dañar la unidad y
anular la garantía.
CAUTION
Do not use this heat pump if any part has
been under water. Immediately call a qualifi ed
service technician to inspect the heater and
replace any part of the control system which
has been under water.
ATTENTION
N’utilisez pas cet appareil s’il a été plongé
dans l’eau, même partiellement. Faites
inspecter l’appareil par un technicien qualifi é et
remplacez toute partie du système de contrôle
et toute commande qui ont été plongés dans
l’eau.
PRECAUCIÓN
No utilice esta bomba de calor si algunos de
sus componentes han estado debajo del agua.
Póngase inmediatamente en contacto con un
técnico de mantenimiento cualifi cado para que
inspeccione el equipo y reemplace cualquier
parte del sistema de control que haya estado
debajo del agua.