Jandy AE-Ti Installation And Operation Manual - page 7
Page 5
2.2 Location
Requirements
2.2.1 Introduction
NOTE Indoor installations require special
considerations for condensate drainage and
venting the cold air produced by the heat
pump. Contact the Jandy Heat Pump Technical
Service Department at (954) 970-4800.
CAUTION
When pool equipment is located below the pool
surface, a leak from any component can cause
large scale water loss or fl ooding. Waterpik
Technologies cannot be responsible for such
water loss or fl ooding or resulting damage.
ATTENTION
Lorsque l’équipement d’une piscine est situé
sous la surface de l’eau, une fuite provenant de
n’importe quel élément peut causer une perte
d’eau importante ou une inondation. Waterpik
Technologiesn’est pas responsable des pertes
d’eau, des inondations ou des avaries causées
par une installation ou un entretien inadéquat.
PRECAUCIÓN
Cuando el equipo de la piscina esté situado
por debajo de la superfi cie de la piscina, la
fuga de cualquiera de los componentes, podría
ocasionar la pérdida de grandes cantidades de
agua o inundación. Waterpik Technologies no
se responsabilizará de dichas pérdidas de agua
o inundaciones, ni de los daños que puedan
derivarse de las mismas.
36
D
C
B
11.5
33
10.75
3.5
A
MODEL
SIZE
DIMENSIONS
"A "
"B "
"C"
"D"
2000
38"
26"
22"
13"
2500
42"
30"
26"
17"
3000
42"
30"
26"
17"
Figure 1.
Jandy AE-Ti Heat Pumps Dimensions
1.7.2 Dimensions
See Figure 1 for a diagram showing the heat
pump’s dimensions and for dimensions to critical
connections.
Section 2. Installation Instructions
2.1 General
Information
Install the Jandy heat pumps in accordance
with the procedures in this manual, local codes and
ordinances, and in accordance with the latest edition of
the appropriate national code. (See Section 1.4, “Codes
and Standards”.)
Correct installation is required to assure safe
operation. The requirements for Jandy heat pumps
include the following:
1. Field assembly (if required).
2. Appropriate site location and clearances.
3. Suffi cient air ventilation.
4. Proper electrical wiring.
5. Adequate water fl ow.
This manual provides the information needed to
meet these requirements. Review all application and
installation procedures completely before continuing the
installation.