Jandy AE-Ti Installation And Operation Manual - page 22
Page 20
5.3
Operating Features of Units with
Optional Chiller
5.3.1
Pool Mode - (Normal Cool)
To operate in Pool-Cool mode, press
POOL
. The
LED indicator will light and the unit will display the
message
POOL TEMPERATURE SET-POINT = XX°
for 5 seconds.
After 5 seconds the display will read
POOL
→
HEAT
and the current pool temperature
.
Press
Heat-
Cool
. The unit will display
POOL TEMPERATURE
SET-POINT = XX°
for 5 seconds. You can change the
set point by pressing the
Up
or
Down
buttons until
the desired set point is displayed. After 5 seconds of
inactivity, the display will read
POOL-COOL
along
with the current pool temperature and the delay time
remaining until the chiller starts. Additionally, the new
set point will be stored in memory. When the water
temperature rises to 1 degree above the temperature
setting
and
after a time delay of 5 minutes, the control
will turn on the chiller circuit.
5.3.2
Pool Mode - (Auto Cool)
The Auto-Cool mode allows the unit to monitor
the temperature of the water 24 hours a day. When
the temperature of the water rises above the desired
temperature setting, the control will then energize the
unit.
To operate in pool mode with the Cooling Auto-
Run feature, press
POOL
. The LED indicator will
light and the unit will display the message
POOL
TEMPERATURE SET-POINT = XX°
for 5 seconds.
After 5 seconds the display will read
POOL
→
HEAT
and the current pool temperature
.
Press
Heat-
Cool
. The unit will display
POOL TEMPERATURE
SET-POINT = XX°
for 5 seconds and the LED on the
button will light. The display will read
POOL
→
COOL
along with the current pool temperature and the delay
time remaining until the chiller starts.
Press
Time-Auto
. The unit will display
POOL
TEMPERATURE SET-POINT = XX°
for 5 seconds
and the LED on the button will light. Change the setting
using the
Up
or
Down
buttons until you reach the
desired set point. After 5 seconds of inactivity, the unit
will display
POOL
→
AUTO-COOL
and the current
pool temperature.
5.3.3
Spa Mode - (Auto Cool)
To operate in Spa Cool mode press
SPA
. The LED
indicator will light on the
SPA
and the
Time/Auto
buttons and unit will display
SPA TEMPERATURE
SET-POINT = XX°
for 5 seconds. Change the setting
using the
Up
or
Down
buttons until you reach the
desired set point. After 5 seconds of inactivity the
display will read
SPA AUTO-HEAT
along with the
current spa temperature and the delay time left until
the chiller starts. Additionally, the new set point will be
stored in memory.
Press
Heat/Cool
. The
Heat/Cool
LED will light
and the display will read
SPA TEMPERATURE SET-
POINT = XX°
for 5 seconds. Change the setting using
the
Up
or
Down
buttons until you reach the desired set
point. The display will read
SPA AUTO-COOL
along
with the current water temperature after 5 seconds of
inactivity. The new set point will be stored in memory.
5.4
Enabling Remote Control with
AquaSwitch Systems and All Other
Dual TStat Remote Systems
NOTE Temperature setting for Pool or Spa are set at
the heat pump.
1. Turn off the control panel.
2. Press and hold the
Time/Auto
,
Up
and
Down
arrow buttons for 5 seconds to enter the setup
menu. The control panel will momentarily display
SETTING 01
then it will display the language that
is used for the display.
NOTE In this mode, pressing and releasing the
SPA
button will step though each setting in the setup
menu. Each press of the
SPA
button will cause
the display to momentarily show the setting
number then show the value for that setting.
Pause between button presses to allow the
control time to respond.
3. Repeatedly press and release the
SPA
button until
the display momentarily reads
SETTING 05
. The
control panel will then display
AQUASWITCH
DISABLED.
4. Press the
Up
arrow button one time to enable
remote control of the unit. The control panel will
then display
AQUASWITCH ENABLED.
5. Press and hold the
Time/Auto
,
Up
and
Down
arrow buttons for 5 seconds to exit the setup menu.
5.5
Enabling Remote Control with
AquaLink RS Systems
NOTE Temperature setting for Pool or Spa are set at
the Aqualink RS indoor controller.
1. Turn off the control panel.