H-1-5. Dust-free –Do not install the Inverter in a dusty environment
where either dust, wood particles or other
filings/shavings are present. These can pulled
into the unit when the cooling fan is operating.
H-1-6. Close to battery/batteries –
Avoid excessive cable lengths but do not install
the Inverter in the same compartment as
batteries. Use the recommended wire lengths
and sizes (see section 7.3). Also do not mount
the Inverter where it will be exposed to the
gases produced by the battery. These gases are
very corrosive and prolonged exposure will
damage the Inverter.
H-2. AC safety Grounding
During the AC wiring installation, AC input and
output ground wires are connected to the
inverter. The AC input ground wire must connect
to the incoming ground from your AC utility
source.
The AC output ground wire should go to the
grounding point for
your loads ( for example, a distribution panel
ground bus ).
H-2-1. Neutral Grounding
H-2-1-1.
120V models: The neutral conductor of the AC output circuit of the
Inverter is automatically connected to the safety
ground during inverter operation. This conforms to
National Electrical Code requirements that
separately derived AC sources (such as inverter and
generators) have their neutral conductors tied to
ground in the same way that the neutral conductor