NautiCharger PM-0600H User Manual - H. Installation:
-8-
G-5. Set the power switch to the ON position. Check the meters
and indicators on the front panel of the inverter. The voltage
bar graph indicate depending on the voltage of the power
source. If does not, check your power source and the
connections to inverter. The other indicators should be off.
G-6. Set power inverter switch to the OFF position, the indicator
lights may blink and the internal alarm may sound
momentarily The is normal. Plug the test load into the AC
receptacle on the front panel of the inverter.
Leave the test load switch off.
G-7. Set power inverter switch to the ON position and turn the test
load on, the inverter should supply power to the load. If you
plan to measure the true output r.m.s. Voltage of inverter, the
meter such as FLUKE 45 BACKMAN
4410 or TRIPLETT 4200 must be used.
H. Installation:
H-1. Where to install
The power inverter should be installed in a location that meets
the following requirements:
H-1-1. Dry – Do not allow water to drip or splash on the inverter.
H-1-2. Col – Ambient air temperature should be between 0°C and
40°C, the cooler the better.
H-1-3. Safe –
Do not install in a battery compartment or other
areas
where
flammable
fumes
may
exist,
such
as
fuel
storage
are
as
or
engine
compartments.
H-1-4. Ventilated – Allow at least one inch of clearance around the
inverter for air flow. Ensure the ventilation
openings on the rear and bottom of the unit are
not obstructed.