NautiCharger PM-0600H User Manual - page 20
-19-
also treat as power unusually so it will automatically Transfer to
DC/AC output this 15% Range can be setting from the Remote
controller
(d) UPS MODE + DELAY MODE + GREEN POWER :
UPS MODE + DELAY MODE :
Same as UPS mode the only different is when AC Transfer
Switch working it won’t complete in 10 m sec it will delay 5
second and than complete.
UPS MODE + DELAY MODE + GREEN POWER :
When AC input cut of the power the AC output is via DC/AC
output and when the AC output load off the DC/AC will turning
into green power mode to reduce the consummation of the
Battery.
High Frequency
Model No.
PM-600H-12xx
PM-600H-24xx
PM-1000H-12xx
PM-1000H-24xx
PM-1500H-12xx
PM-1500H-24xx
PM-2000H-12xx
PM-2000H-24xx
PM-3000H-12xx
PM-3000H-24xx
Continuous
Output
power
600W 1000W 1500W 2000W 3000W
Output
power
surge
800W 1400W 2000W 2800W 4200W
AC Output voltage
100/110/120V ± 2% 220/230/240V ± 2% DIP switch select
Output voltage Regulation
-8% / ± 3% All models
Output frequency
50 / 60 Hz selectable ±0.05% Accuracy
Output Wave form
Pure Sine Wave < 3% THD
Efficiency (Full Load)
83%~85%
No Load power consumption
<1.5W (In power saving mode.)
Input voltage range
10V – 16VDC,20V-32VDC
Power saving recovery time
1 second
AC Transfer time (UPS-mode)
< 10msec max
LED status indicators
High/Low battery shutdown, over temperature shutdown, overload shutdown /
input DC voltage scale meter & output watts percent scale metter.
Protection Feature
* Remote controller option.
Over load, short circuit, over/under input voltage, over temperature, reverse
input polarity (by fuse).
RS485 Remote controller
Power output ON/OFF, green power mode, reset, error message, …etc.
Operation temperature range
0~50 (32°~122°F)
Storage temperature range
-30 ~70 (-22°~158°F)
Dimensions L x W x Hmm
370x270x120 420x270x120
470x270x120
470x270x190 530x270x190
Weight
9.92 (Lbs.)
4.5 (Kgs)
12.13 (Lbs.)
5.5 (Kgs)
15.43 (Lbs.)
7 (Kgs)
22.05 (Lbs.)
10 (Kgs)
26.46 (Lbs.)
12 (Kgs)
Remote controller is optional