NautiCharger PM-0600H User Manual - Warning!
-10-
from the utility is tied to ground at the AC breaker
panel. For models configured with a transfer relay,
when AC utility power is present and the Inverter is
in bypass mode, this connection (neutral of the
Inverter’s AC output to input safety ground )is not
present so that the utility neutral is only connected to
ground at your breaker panel, as required.
H-2-1-2.
230V models: There is no connection made inside the Inverter from
either of the line conductors (line or neutral) to the
safety ground.
Ground Fault Circuit Interrupters (GFCI’S):
Installations in Recreational Vehicles (for North American
approvals) will require GFCI protection of all branch circuit
connected to the AC output of the hardwire terminal equipped
Inverter. In addition, electrical codes require GFCI protection of
certain receptacles in residential installations. While the true sine
wave output of the Inverter is equivalent to the waveform
provided by utilities, compliance with UL standards requires us to
test and recommend specific GFCI’s. State power has tested the
following GFCI-protected 15A receptacles and found that they
functioned properly when connected to the output of the Inverter.
H-3. Making DC Wiring Connections :
Follow this procedure to connect the battery cables to the DC
WARNING!
Do not operate the power inverter without
connecting it to ground.
Electrical shock hazard may result.