6
Delivery Status
The S3 is delivered as follows:
-
a factory set-up (see 6.1) is installed,
-
a factory firmware is installed
-
a factory license (see 6.2) is installed (from FW-Version 00.07.00.63; NMP 6.5),
-
the customer specific configuration is installed (if ordered).
The current firmware version can be downloaded from
www.novatec.de
> Downloads.
The firmware license for the current firmware is delivered by email as soon as the S3 is dispatched.
6.1 Factory Set-Up
DHCP with option 129 is activated in the factory set-up.
The system will try for approx. one minute to reach the DHCP server after being restarted. If the DHCP
request runs fail the system will fall back into the following IP default adjustment
-
IP-address:192.168.127.254
-
Subnet mask: 255.255.0.0
-
Default-Gateway:192.168.1.254.
Please consider the following with modifications of the factory set-up:
If no DHCP server is available under „System IP Option“ in the configuration the existing entry „DHCP on“
has to be changed to „DHCP off“.
6.2 Firmware-License
From firmware version 00.06.07.00 you need a firmware license to ensure the functionality of the S3. If
this license is missing telephony is not possible and only remote access is possible.
The license is already on board if the S3
a. was delivered with firmware 00.07.00.63 or higher or
b. was delivered with a firmware
The license data has to be uploaded onto the system with the NovaTec configuration interface if
a. the S3 was delivered with a firmware
b. an upgrade onto firmware 00.07.00.63 or higher is effected or
c. the current firmware is to be installed (see 6)
The following points have to be considered when updating S3-systems:
a. Systems with a firmware version older/smaller than 00.06.07.00:
An update onto firmware 00.06.07.00 or higher always requires a license key. The license cannot
be readout of the system or stored.
b. Systems configured with NMP 6.3.2 or 6.4:
To copy the configuration onto the target system a license key is required irrespective of the firm-
ware version. The license key has to be uploaded uniquely with the NovaTec configuration inter-
face into the data base before the configuration can be transferred. The license cannot be readout