the configuration. If the S3 is in default mode after the restart the data base file was damaged.
The LED`s in the system show the operational condition of the system. Should the system be in default
mode please reconnect the S3 with the computer and correct the configuration before transferring the
altered data base file onto the S3.
7.1 Firmware update via Trace Info Client (with USB or V.24):
1. Start your network services
2. A blue triangle appears in the Windows Systems tray
3. Right-click on the triangle and select settings
4. Activate the option „use COM port“ and set the COM port of your PC resp. the USB interface
5. Start the Trace Info Client
6. Click „Settings“
7. Enter „localhost“ as hostname and port 800. Confirm with "OK".
8. Click "Connect"
9. Enter „technik" as username and the password of the target system (as the delivery state is
without password the box remains empty)
10. Select "V.24 / USB" in the network box and confirm with "OK"
11. As soon as the connection is made new flags appear in the Trace Info Client
12. Select the flag "Diagnosis"
13. Click the button "Firmware" and select the firmware file you wish to transfer to the target system
14. A progress window appears whilst the firmware is uploaded
15.
The firmware is target system resident. The message "Updating Firmware on Target" appears
. Do
not switch off the system as long as this message is shown elsewise the system will not work after
the reset!
16. A notice will pop up telling you that the upload was successful and a reset is necessary.
17. Select „Systemreset“ (as long as the system reset has not been affected the system will run with
the previous firmware).