Figure 4–1 is a sample floor plan, showing the space required for the
system units and the minimum recommended service area for the printer.
Figure 4–1 Floor plan (minimum maintenance distances shown)
If your specific work area does not meet this minimum floor plan, consult
with customer support to consider other possible arrangements.
The system should not be located near heavy machinery (such as
generators) that may cause electrical interference or high vibration levels.
The system should be protected from sprinklers or pipes carrying liquids
above the system. Similarly, do not place a Water Jet (used for cleaning
models) within 5 meters (16 feet) of the printer.
The server workstation must be located within 5 meters (16 feet) of the
Alaris printer. The monitor, keyboard and mouse of the workstation are
shared with the Alaris computer (the keyboard and the mouse must be
USB‐type devices).
Shelves and cabinets may be located in the vicinity of the Alaris system to
allow convenient storage of tools, parts, accessories, manuals and
containers or model/support material.
9
'10"
300 cm
9
'10"
300 cm
60 cm
Alaris
Printer
24"
See Section 4.4
24"
60 cm
24"
60 cm
Service
Area
24"
60 cm
Server
Workstation
Switchbox
The temperature requirements for material storage are stated in Section 5.10.1,
Storage and Transport Conditions on page 18.