Pacific Energy NEO 1.6 Installation And Operating Instructions Manual - Removal
15
5055.900AS_120515-20
NEO 2.5
Chimney connector pipe should be disconnected from stove to clean and inspect. Only if this is not possible should you remove
baffle assembly.
CAUTION: Ceramic blanket insulation is located on top of baffle. Do not use a vacuum in this area.
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION REMOVED.
Removal
Remove retaining pin located at the rear top of the firebox, just below the baffle. Lift baffle up and pull forward to disconnect from
the supply tube. Tilt baffle sideways to drop down and remove from firebox. Inspect gasket between baffle and supply tube. If
necessary, replace with gasket SSER.1395 available from your Pacific Energy dealer. Re-install baffle assembly in reverse order.
The two side pieces of insulation must be tight against the siderails.
WARNING
: Sweep/Clean chimney with baffle installed or be sure to plug the top of the baffle tube in the back of the firebox
before sweeping or cleaning. Failure to prevent ash or soot from falling into the baffle tube will cause incorrect operation and
will lead to premature burn out of the tube or baffle.
It is recommended to inspect the liner and connector monthly and to have the liner cleaned annually or more
frequently if required.
Cover the opening at the top of the baffle supply tube when cleaning the chimney liner. If debris gets into the tube
Baffle Removal
Disposal of Ashes
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed outside on a
non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed
of by burial in soil or otherwise locally dispersed, they should be retained in a closed container until all cinders have thoroughly
cooled. Other waste should not be placed in this container.