Replace cleaning
Roller
The fuser cleaning roller needs to be
replaced.
Replace the fuser
cleaning roller.
Also, this message
occurs when the user
replaces the fuser oil
bottle and cleaning
roller, but only resets
the fuser oil on the
control panel.
»
Note:
Reset the
fuser cleaner under
Operator Control/
Consumables/Item
Replaced/Cleaning
Roller.
Replace cyan Toner
The cyan toner cartridge is low.
Replace the cyan toner
cartridge, or continue
printing until
Cyan
toner Empty
displays.
»
Note:
Reset cyan
toner under
Operator Control/
Consumables/Item
Replaced/Cyan
Toner.
Replace fuser
The fuser needs to be replaced.
Replace the fuser.
»
Note:
Reset the
fuser under
Operator Control/
Consumables/Item
Replaced/Fuser.
This message...
indicates...
Do this...