80 DEVICE PROGRAMMING
Use this mode to program Powerline Carrier Devices or zone lists for Chime by Zone feature. It is also used to
program the Remote Services Multi-mode (e-mail) event triggers. Press
✻
80 while in programming mode.
Note:
Entering a number other than the one specified may give unpredictable results.
80
80
80
80
DEVICE
DEVICE
DEVICE
DEVICE PROG
PROG
PROG
PROG MENU
MENU
MENU
MENU
Powerline Carrier Device Programming
0 = Exit mode, upon which this prompt blinks.
1 = Enter mode
A01
A01
A01
A01
DEVICE
DEVICE
DEVICE
DEVICE NUMBER
NUMBER
NUMBER
NUMBER
Device Number
Enter the 2-digit device number to be programmed
01-08 = X10 device number
09-16 = Multimode (e-mail) event triggers
[✻] = Continue
00 = Exit Device Programming mode (displays blinking 80; enter ✻ + desired data field or
menu mode number)
b
DEVICE
DEVICE
DEVICE
DEVICE ACTION
ACTION
ACTION
ACTION
Device Action
Enter the 1-digit action, 0-3, for the device being programmed (current action is displayed).
0 = No response
3 = Pulse on and off
1 = Close for 2 seconds
[✻] = Continue
2 = Close and stay closed
[#] = Return to previous prompt
C
C
C
C
START
START
START
START EVENT
EVENT
EVENT
EVENT TYPE
TYPE
TYPE
TYPE
Start Event Type
(If applicable)
Enter the 1-digit start event type, 0-3, for the device being programmed.
0 = Not used
3 = Trouble
1 = Alarm
[
✻
] = Continue
2 = Fault
[#] = Return to previous prompt
d
START
START
START
START ZONE
ZONE
ZONE
ZONE LIST
LIST
LIST
LIST
Start Zone List
(If applicable)
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[
✻
] = Continue
[#] = Return to previous prompt
E
E
E
E
START
START
START
START ZONE
ZONE
ZONE
ZONE TYPE
TYPE
TYPE
TYPE
Start Zone Type
(If applicable)
Enter the 2-digit start zone type for the device being programmed (see Powerline Carrier
Device Worksheet for zone type/system operation codes later in this manual).
[
✻
] = Continue
[#] = Return to previous prompt
F
F
F
F
STOP
STOP
STOP
STOP ZONE
ZONE
ZONE
ZONE LIST
LIST
LIST
LIST
Stop Zone List
(If applicable)
Enter the 1-digit zone list number, 1-3, or 0 if not used, for the device being programmed.
[
✻
] = Continue
[#] = Return to previous prompt
1A
1A
1A
1A
STOP
STOP
STOP
STOP ZONE
ZONE
ZONE
ZONE TYPE
TYPE
TYPE
TYPE
Stop Zone Type
(If applicable)
Enter the 2-digit stop zone type for the device being programmed (see Powerline Carrier
Device Worksheet for zone type/system operation codes later in this manual).
[
✻
] = Continue to Device Number prompt (A)
[#] = Return to previous prompt