Safewatch QuickConnect Plus Programming Manual - page 4
- 4 -
Data Field Display
Function& Programming Options
[ ] = Programmed Table 1 Default Values
ZONE SOUNDS AND TIMING (✻31– ✻39)
31
31
31
31
SINGLE
SINGLE
SINGLE
SINGLE ALARM
ALARM
ALARM
ALARM SND
SND
SND
SND
Single Alarm Sounding/Zone
UL installations = 0
† [0]
0 = Alarm Sounding Per Zone will be the same as the Swinger Shutdown” set in field *92;
1 = yes, limit once per arming period (also applies to long range radio output if “0” is
selected in ✻91 field)
32
32
32
32
FIRE
FIRE
FIRE
FIRE SND
SND
SND
SND TIMEOUT
TIMEOUT
TIMEOUT
TIMEOUT
Sounder Timeout
† [0]
0=timeout; 1=no timeout
33
33
33
33
ALRM
ALRM
ALRM
ALRM SND
SND
SND
SND TIMEOUT
TIMEOUT
TIMEOUT
TIMEOUT
Alarm Bell Timeout
UL installations = 1 (4 min) minimum
† [1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min
34
34
34
34
EXIT
EXIT
EXIT
EXIT DELAY
DELAY
DELAY
DELAY TIME
TIME
TIME
TIME
Exit Delay
UL installations = 60 seconds max.
|
† [60]
45-96 = exit delay time (in seconds)
97 = 120 seconds
Note:
The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value “60”, which is displayed on the keypad, and advances to
the next field.
SIA:
Must be set to a minimum of 45 seconds.
35
35
35
35
ENTRY
ENTRY
ENTRY
ENTRY DELAY
DELAY
DELAY
DELAY 1 1 1 1
Entry Delay 1
(zone type 01)
UL installations = 45 seconds max.
|
† [30]
30-96 = entry delay 1 time (in seconds)
97 = 120 seconds
98 = 180 seconds
99 = 240 second
Note:
The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value “30”, which is displayed on the keypad, and advances to
the next field.
SIA:
The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 entered in
Field *35 and the burglary abort window entered in *50 should not exceed 1 minute.
36
36
36
36
ENTRY
ENTRY
ENTRY
ENTRY DELAY
DELAY
DELAY
DELAY 2
2
2
2
Entry Delay 2
(zone type 02)
UL installations = 45 seconds max.
|
† [30]
30-96 = entry delay 2 time (in seconds)
97 = 120 seconds
98 = 180 seconds
99 = 240 second
Note:
The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value “30”, which is displayed on the keypad, and advances to
the next field.
SIA:
The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 2 entered in
Field *36 and the burglary abort window entered in *50 should not exceed 1 minute.
38
38
38
38
CON
CON
CON
CONF
F
F
F ARM
ARM
ARM
ARM ING
ING
ING
ING DING
DING
DING
DING
Confirmation of Arming Ding
Note:
Confirmation ding only sounds when Safewatch QuickConnect Plus is Armed Away or disarmed
after being Armed Away. If Safewatch QuickConnect Plus is armed by RF button (key fob), a
confirmation ding occurs immediately after arming regardless of field
✻
38 settings. If Safewatch
QuickConnect Plus is disarmed by RF button (key fob), additional disarming confirmation ding occurs
immediately after disarming and is longer than arming confirmation ding.
† [0]
0 =
no arming confirmation ding after arming system by Safewatch QuickConnect Plus keypad or RF
keypad
;
1 = arming confirmation ding after arming system by Safewatch QuickConnect Plus keypad
or RF keypad;
2 = arming confirmation ding after arming from RF keypad only
† Entering a number other than the one specified may give unpredictable results.