Safewatch QuickConnect Plus Programming Manual - page 7
- 7 -
Data Field Display
Function& Programming Options
[ ] = Programmed Table 1 Default Values
51
51
51
51
PERIOD
PERIOD
PERIOD
PERIOD T
TT
TEST
EST
EST
EST REP
REP
REP
REP
Periodic Test Report
(enter Test Code in field ✻64)
† [0]
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days
52
52
52
52
TEST
TEST
TEST
TEST REP
REP
REP
REP OFFSET
OFFSET
OFFSET
OFFSET
First Test Report Offset
† [2]
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours
53
53
53
53
SESCOA/RADIONICS
SESCOA/RADIONICS
SESCOA/RADIONICS
SESCOA/RADIONICS
SESCOA/Radionics Select
[0]
0 = Radionics (0–9, B–F reporting);
1 = SESCOA (0–9 only reporting). Select 0 for all other formats.
54
54
54
54
LACK
LACK
LACK
LACK OF
OF
OF
OF USAGE
USAGE
USAGE
USAGE
Lack of Usage Notification
[0]
0 = Disabled
1 = 1 day
2 = 7 days
3 = 27 days
4 = 90 days
5 = 180 days
6 = 365 days
55
55
55
55
REPORT
REPORT
REPORT
REPORT CHANNELS
CHANNELS
CHANNELS
CHANNELS
Reporting Channels
[0]
0 = Telco Line (no Radio)
1 = LRR/IP(Digital Communication only) and Telco Line
3 = LRR/IP (Digital Communication only) (no Telco Line)
5 = LRR/IP (Digital Communication with AAV) (Telco Line connections for 2-way voice
session only, if applicable)
57
57
57
57
FALSE AL
FALSE AL
FALSE AL
FALSE ALA
A
A
ARM OPTS
RM OPTS
RM OPTS
RM OPTS
False Alarm Options
[7]
Value
Cancel Alarm Display Auto Stay Arming Exit Time Restart/Reset
0 =
Disabled
Disabled
Disabled
1 =
Disabled
Disabled
Enabled
2 =
Disabled
Enabled
Disabled
3 =
Disabled
Enabled
Enabled
4 =
Enabled
Disabled
Disabled
5 =
Enabled
Disabled
Enabled
6 =
Enabled
Enabled
Disabled
7 =
Enabled
Enabled
Enabled
Note:
The control validates the data entered in this field. If the selection is not valid it will emit a single
long beep indicating that the selection has been rejected. The control replaces the selection
with the default value “7”, which is displayed on the keypad, and advances to the next field.
58
58
58
58
RF
RF
RF
RF JAM
JAM
JAM
JAM DETECTION
DETECTION
DETECTION
DETECTION
RF Jam Detection
Note:
For event logging option 2 must be selected.
[0]
0 = no RF Jam Detection; 1 = RF Jam Detect on, no CS report;
2 = RF Jam Detect on with CS report (if trouble/restore report is enabled in fields
✻
60,
✻
71)
† Entering a number other than the one specified may give unpredictable results.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (✻59–✻76, & ✻89):
With a 3+1 or 4+1 Standard Format:
Enter a code in the first box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B, "#+12" for C,
"#+13" for D, "#+14" for E, "#+15" for F.
A "0" (not "#+10") in the first box will disable a report.
A "0" (not "#+10") in the second box will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format:
Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.
A "0" (not "#+10") in the second box will eliminate the expanded message for that report.
A "0" (not "#+10") in both boxes will disable the report.
With ADEMCO Contact ID Reporting:
Enter any digit (other than "0") in the first box, to enable zone to report (entries in the second boxes
will be ignored). A "0" (not "#+10") in the first box will disable the report.
Examples:
For Code 3 (single digit), enter:
3 | 0
For Code 3 2 (two digits), enter:
3 | 2
For Code B 2 (Hexadecimal), enter: #+11 | 2