Safewatch QuickConnect Plus Programming Manual - page 18
- 18 -
POWERLINE CARRIER DEVICES WORKSHEET FOR ✻
✻
✻
✻
80 and ✻
✻
✻
✻
81
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.
UL
Powerline Carrier Devices have not been evaluated by UL.
✻
80
OUTPUT DEVICES
Fill in the required data on the worksheet on below and follow the programming procedure in the Installation
Instructions as you enter the data during the displays and prompts that appear in sequence.
Note:
If using P.C.L.D. (X10 devices), Field ✻25 must be programmed with a House Code.
START
either or both
STOP
either or both
DEVICE
NUMBER
ACTION
(aa)
EVENT
ZONE
TYPE
(et)
LIST
(zl)
ZONE TYPE
SYS OPERATION (zt)
RESTORE
ZONE LIST (zl)
ZONE TYPE/
SYS OPERATION (zt)
P.L.C.D.*† 01
P.L.C.D.*† 02
P.L.C.D.*† 03
P.L.C.D.*
04
P.L.C.D.*
†05
P.L.C.D.*† 06
SYS. P.L.C.D.*† 07
SYS. P.L.C.D.*† 08
[2]
[33]
[36]
E-mail event trigger 09
E-mail event trigger 10
E-mail event trigger 11
E-mail event trigger 12
E-mail event trigger 13
E-mail event trigger 14
E-mail event trigger 15
E-mail event trigger 16
[2]
[33]
[36]
Note:
If using an X10 Powerhouse Security SH10A Siren as device 08, you must change the action default to “3” if using default table 4.
Where:
A = DEVICE ACTION
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
ET = EVENT TYPE
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
Z L = ZONE LIST
1, 2, or 3 (from Field ✻81) or 0 = Not Used.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
"STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It need
not be same list as used for START.
Note:
Do not assign zones with types 20, 21, or 22 to a zone list.
ZT = ZONE TYPE/
SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used
01 = Entry/Exit#1
02 = Entry/Exit#2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hour Silent
07 = 24 Hour Audible
08 = 24 Hour Aux
09 = Fire Zone without Verification
10 = Interior with Delay
14 = Carbon Monoxide
16 = Fire with verification
24= Silent Burglary
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + FF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Alarm (except ZT=08 or 09)
36 = *At Bell Timeout
38 = Chime
39 = Any Fire Alarm
* Or at Disarming, whichever occurs earlier.
40 = Bypassing
42 = System Battery Low
43 = Communication Failure
52 = Kissoff
58 = Duress
Note:
In normal operation mode:
For Devices 01-06:
Function + Lights On + NN
Function + Lights Off + NN
For Devices 07 and 08:
Code + Function + Lights On + NN
Code + Function + Lights Off + NN
NN = 2- digit device number
(Entry starts Device NN)
(Entry stops Device NN)
✻
✻
✻
✻
81
ZONE LISTS FOR OUTPUT DEVICES
Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter
the data during the displays and prompts that appear in sequence.
Zone List 1
: Started or stopped by zone numbers (enter 00 to end entries).
.etc. [28][32]
Zone List 2
: Started or stopped by zone numbers (enter 00 to end entries).
.etc
.
[29][33]
Zone List 3
: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)
.
etc. [02][03]
Note
: Any zone in "ZT" going into alarm, fault, or trouble will activate device with the exception of 01, 02
when the system is in alarm. Any zone that restores will stop device action.