Samsung AQ07P8GE Training Manual - page 31
30 | SAMSUNG
INSTALLATION
5
Installation Diagram of Indoor Unit and Outdoor Unit
(Cont.)
5-2-5. Installing and Connecting the Indoor Unit Drain Hose
Care must be taken when installing the drain hose for the indoor unit to ensure that any condensed water is correctly drained out-
side. When passing the drain hose through the 65mm hole drilled in the wall, check that none of the following situation occur.
The hose must
NOT slope
upwards.
The end of the drain
hose must NOT be
placed in water.
Do NOT bend the
hose in different
directions.
Keep a clearance of at
least 5cm between the
end of the hose and the
ground.
5cm less
Do NOT place the
end of the drain hose
in a hollow.
1. If necessary, connect the 2-meter extension to the drain hose.
2. If you are using the extension, insulate the inside part of the extension
drain hose with a shield.
3. Pass the drain hose under the refrigerant piping, taking care to keep the
drain hose tight.
4. Pass the drain hose through the hole in the wall, making sure that it is
sloping downwards, as shown in the illustrations above.
The hose will be fixed permanently into
position once the whole installation has been
tested for gas leaks.
Shield
Drain hose
Extension drain hose
To install the drain hose, proceed as follows
DB98_08187A(1)_S_23~56 3/27/03 2:41 PM Page 30