6-2-4. Sleeping Operation
●
AT COOLING MODE
When you set the sleep mode, the following movement will start
to avoid over cooling.
◆
The indoor fan speed is fixed by setting the remote controller.
◆
The setting temperature will rise by 1°C at the starting of
operation and by 1°C one hour later.
◆
The operation will stop after 6 hours.
●
AT HEATING MODE
When you set the sleep mode, the following movement will
start to avoid overheating.
◆
The indoor fan speed is fixed by setting the remote
controller.
◆
The setting temperature will be dropped by 1°C at the
starting of operation and by 1°C one hour later.
◆
The operation will stop after 6 hours.
6-2-5. Turbo Operation (Cooling or Heating Mode)
If turbo operation is selected during heating or cooling mode, compressor is operated for 30minutes regardless of room temperature.
After 30minutes of turbo operation the unit will operate in normal state