    Medi-call unit installation manual medi-call v2.0 - v2.7 installation manual.

  • Page 2

    Medi-call v2.0 – v2.7 installation manual 1 © copyright smartlink international pty ltd february 2006 475 nepean highway, brighton vic 3186 australia telephone: +61 3 9596 0770 facsimile: +61 3 9596 8195 e-mail: smartlink@smartlink.Com.Au web site: www.Smartlink.Com.Au to the best of our knowledge, ...

  • Page 3

    Medi-call v2.0 – v2.7 installation manual 2 1 . T a b l e o f c o n t e n t s 1. Table of contents .......................................................................................... 2 2. Introduction ...............................................................................................

  • Page 4: Radio Key Pendants

    Medi-call v2.0 – v2.7 installation manual 3 2 . I n t r o d u c t i o n your smartlink unit has been designed to provide you with the freedom and peace of mind in that, should you need assistance or help, it is available to you 24 hours a day with the simple press of a button. The modern slim line d...

  • Page 5

    Medi-call v2.0 – v2.7 installation manual 4 3 . S m a r t l i n k f e a t u r e s top view bottom view.

  • Page 6: 4.2  Programming Options

    Medi-call v2.0 – v2.7 installation manual 5 4 . P r o g r a m m o d e to enter one of the programming modes, the smartlink unit must be turned off by unplugging the mains and the battery switch must also be off. There are two types of programming modes: 1. Product programming - which programs smartl...

  • Page 7: System Programming Options

    Medi-call v2.0 – v2.7 installation manual 6 5 . P r o g r a m m i n g o p t i o n s 5.1 programming main menu options option page descriptions 7 keys (pendants) programming options 9 detectors programming options 11 hardwired inputs programming options 11 auxiliary outputs programming options 12 pho...

  • Page 8

    Medi-call v2.0 – v2.7 installation manual 7 5.2 programming sub menu options the sub menu options are displayed for each particular main menu option. 5.2.1 keys (pendants) programming options option description (note: ademco and british dtmf versions) user key 1 (pendant) programming un-programmed n...

  • Page 9

    Medi-call v2.0 – v2.7 installation manual 8 option description (note: contact id version only) user key 1 (pendant) programming un-programmed no radio key pendant has been programmed for user key 1 panic where on = arm off = disarm panic = emergency duress where on = arm off = disarm panic = silent ...

  • Page 10

    Medi-call v2.0 – v2.7 installation manual 9 5.2.2 detectors programming options option description (note: ademco and british dtmf versions) detector 1 programming unprogrammed no detector has been programmed for detector 1. Fire 24 hour alarm, always active (initiates emergency). Alarm in-active whe...

  • Page 11

    Medi-call v2.0 – v2.7 installation manual 10 option description (note: contact id version only) detector 1 programming unprogrammed no detector has been programmed for detector 1. Fire 24 hour alarm, always active. Alarm in-active when disarmed, active when armed. (v2.0 – v2.5 only) home in-active w...

  • Page 12

    Medi-call v2.0 – v2.7 installation manual 11 5.2.3 hardwired inputs programming options option description input 1 program (default d = disabled) - reports to channel 5 disabled - normally open hardwired connection between common and inputs enabled – initiates emergency when closed (v2.3 ademco onwa...

  • Page 13

    Medi-call v2.0 – v2.7 installation manual 12 5.2.5 phone numbers programming options there are 4 phone numbers, a primary number “n1”, a secondary number “n2” and another two phone numbers “n3” and “n4”. This reporting is used to transmit alarms from a subscriber’s site to a control centre via the t...

  • Page 14

    Medi-call v2.0 – v2.7 installation manual 13 5.2.6 preference programming options option description client account number (default - unprogrammed) note - ademco & contact id versions - up to 4 digits maximum. Note - british dtmf version only - up to 12 digits maximum. Digits 0 – 9 1. “ca” is displa...

  • Page 15

    Medi-call v2.0 – v2.7 installation manual 14 option description entry time (default 10 = 10 seconds) note: contact id version only seconds - time between a detector triggering and smartlink unit alarming. 1. “en” is displayed on the smartlink unit. 2. Press the help button to view programmed time. 3...

  • Page 16

    Medi-call v2.0 – v2.7 installation manual 15 option description inactivity timer (default 0 = disabled) 0 – 200 = 0 – 200 hours or 201 – 255 = 1 – 55 minutes note: interval where at least one activity signal is expected from each individual dementia key or any inactivity detector. If a number greate...

  • Page 17

    Medi-call v2.0 – v2.7 installation manual 16 option description answer call (default 6 = 6 minutes) 3 minutes 6 minutes 9 minutes time after an alarm, the voice circuits are enabled for any incoming calls to be automatically answered. 1. “ac” is displayed on the smartlink unit. 2. Press the help but...

  • Page 18

    Medi-call v2.0 – v2.7 installation manual 17 option description rings detected (default 2 = 2 rings) 2 – 9 rings to detect before automatically answering after an alarm event. 1. “rd” is displayed on the smartlink unit. 2. Press the help button to view programmed number of rings. 3. Pressing the hel...

  • Page 19

    Medi-call v2.0 – v2.7 installation manual 18 5.2.7 system programming options option description system check (check signal strength of pendants and detectors) no pendants or detectors received 1 to 9 signal strength 1. “sc” is displayed on the smartlink unit. 2. Press the help button. Smartlink uni...

  • Page 20

    Medi-call v2.0 – v2.7 installation manual 19 option description speaker volume (default 3 = loudest) quietest quiet loud loudest 1. “sp” is displayed on the smartlink unit. 2. Press help button to view programmed speaker volume. 3. Pressing help again to step through speaker volume (0, 1, 2 or 3). 4...

  • Page 21

    Medi-call v2.0 – v2.7 installation manual 20 5.2.8 report programming options option description (note: ademco version only) unit help (red) button reporting channel (default 16) (v2.0 to v2.2) channel 1 – 8 initiates emergency (default c6 = channel 6) (v2.3 onwards) channel 1 – 8 initiates emergenc...

  • Page 22

    Medi-call v2.0 – v2.7 installation manual 21 restores enabled (default e) note: ademco and contact id versions disable – no restores are sent to the control centre. Enable - restores are sent to the control centre. 1. “re” is displayed on the smartlink unit. Press the help button to view programmed ...

  • Page 23

    Medi-call v2.0 – v2.7 installation manual 22 5.2.9 door bell tune programming options (v2.5 onwards) door bell 1 tempo (default = 50) 0 – 255 (duration of a typical note in 10msec intervals). Note: if set to 0 then disabled door bell 1 tune entirely. 1. “p1” is displayed on the smartlink unit. 2. Pr...

  • Page 24: 6 .  A L A R M S

    Medi-call v2.0 – v2.7 installation manual 23 6 . A l a r m s 6.1 device alarms alarms turn on the help (red) button to maximum brightness and after the reset time, the help (red) button will turn off or back to the soft glow. The auxiliary outputs “o1” – “o3” will be enabled and remain for their ind...

  • Page 25

    Medi-call v2.0 – v2.7 installation manual 24 6.1.2 detector alarm (display “a1” to “a8”) when disarming after an alarm, the smartlink unit will indicate if a detector alarm has occurred. The speaker will beep rapidly for 5 seconds. This warning may indicate that an intruder is still present. The sou...

  • Page 26: 6.5  System Alarms

    Medi-call v2.0 – v2.7 installation manual 25 6.5 system alarms system alarms are indicated by flashing the alarm type on the status display. The speaker/beeper also beeps for 3 seconds. Note: system alarms are not indicated when the system is armed or in home mode. Ademco and british dtmf versions –...

  • Page 27: 7 .  D I A L L E R

    Medi-call v2.0 – v2.7 installation manual 26 7 . D i a l l e r 7.1 remote dtmf auxiliary output control the smartlink unit is capable of remotely controlling the auxiliary outputs by using dtmf codes. Auxiliary outputs “o1” – “o3” can be remotely controlled in all modes except program mode. The auxi...

  • Page 28: 7.4  Alarms Reported

    Medi-call v2.0 – v2.7 installation manual 27 7.2 phone numbers “n1” to “n4” there are 4 phone numbers, a primary number “n1”, a secondary number “n2” and another two phone numbers “n3” and “n4”. This reporting is used to transmit alarms from a subscriber’s site to a control centre via the telephone....

  • Page 29: 8.1  Normal/disarm Mode

    Medi-call v2.0 – v2.7 installation manual 28 8 . O p e r a t i o n m o d e 8.1 normal/disarm mode ademco and british dtmf versions: press the smartlink unit cancel (green) button to disarm or the off button on a radio key pendant (any programmed user key with option “sc” security). Speaker beeps 3 t...

  • Page 30

    Medi-call v2.0 – v2.7 installation manual 29 9 . V o i c e a n n u n c i a t o r 9.1 “hands free” phone operation ademco and british dtmf versions: • uses the smartlink cancel (green) button to answer or hang up an incoming telephone call “hands free”. • uses the panic button (keys programmed with “...

  • Page 31: 10.2  Inactivity Monitor

    Medi-call v2.0 – v2.7 installation manual 30 9.3 voice only reports “n3” and “n4” when an alarm is to be sent, the smartlink unit will dial the programmed phone numbers “n3” and “n4” eg: mobile phone etc. Beeps will be heard on the receiving phone every 5 seconds. The person receiving the call must ...

  • Page 32

    Medi-call v2.0 – v2.7 installation manual 31 1 1 . D i a l l e r r e p o r t i n g 11.1 ademco high speed extended reporting this reporting is used to transmit alarms from a subscriber’s site to a control centre via the telephone. The transmission is done using dtmf tones. 14 digits are sent to repo...

  • Page 33: 11.2  Contact Id Reporting

    Medi-call v2.0 – v2.7 installation manual 32 11.2 contact id reporting this reporting is used to transmit alarms from a subscriber’s site to a control centre via the telephone. The transmission is done using dtmf tones. 14 digits are sent to report an alarm. The format is as follows: ssss 18 q xyz g...

  • Page 34

    Medi-call v2.0 – v2.7 installation manual 33 11.3 british dtmf (universal ) reporting this reporting is used to transmit alarms from a subscriber’s site to a tunstall base station via the telephone line. The transmission is done using dtmf tones. 24 digits are sent to report an alarm. The format is ...

  • Page 35

    Medi-call v2.0 – v2.7 installation manual 34 1 2 . U p / d o w n l o a d r e m o t e p r o g r a m m i n g the smartlink unit may be remotely programmed via a telephone modem link. Remote programming is enabled when in program mode and if the “ud” up/download option is enabled (enabled all the time)...

  • Page 36: 13.1  Normal Operation

    Medi-call v2.0 – v2.7 installation manual 35 1 3 . U s i n g s m a r t l i n k 13.1 normal operation your smartlink unit will normally look like this: the mains on light should be on and the cancel (green) button will flash every 4 seconds. 13.2 to call for help you can make your smartlink call for ...

  • Page 37: W A R N I N G S

    Medi-call v2.0 – v2.7 installation manual 36 1 4 . D i s p l a y s a n d w a r n i n g s help (red) button flashing quickly while beeping your smartlink unit is about to send a help message to your control centre. Help (red) button flashing slowly your smartlink unit has sent a help message to your ...

  • Page 38: Smartlink Unit

    Medi-call v2.0 – v2.7 installation manual 37 1 5 . S p e c i f i c a t i o n s smartlink unit ƒ dimensions ƒ weight ƒ quiescent current ƒ ac plug pack ƒ battery backup ƒ radio receiver ƒ sensitivity ƒ range 286 x 174 x 38 mm 590gms (including battery) 1ma 17v ac 300ma with integral earth 8.4v rechar...