Smartlink MEDI-CALL UNIT Installation Manual - 8.1 Normal/disarm Mode
Medi-Call V2.0 – V2.7 Installation Manual
28
8 . O P E R A T I O N M O D E
8.1 NORMAL/DISARM MODE
Ademco and British DTMF Versions:
Press the SmartLink unit CANCEL (Green) Button to DISARM or the OFF Button on a Radio Key Pendant (any
programmed User Key with option “Sc” SECURITY).
Speaker beeps 3 times and status display “0” for 4 seconds.
In Disarmed Mode, the CANCEL (Green) Button will flash once every 4 seconds to indicate the SmartLink unit is
functioning normally.
NOTE: If the option “CS” CALL SEND (Ademco Version only) is Enabled, then the SmartLink unit CANCEL (Green)
Button send a non valid Ademco Manual Test Call (NNNN/ 5555555 / 7) when pressed.
Contact ID Version:
Press OFF Button on a Radio Key Pendant (any programmed User Key with options “Pn” PANIC, “dP” DELAY PANIC or
“du” DURESS) to DISARM.
Speaker beeps 3 times and status display “0” for 4 seconds.
The SmartLink unit will not be Disarmed from HOME Mode if the SmartLink unit is in Voice Report or Hands Free
operations. First Voice Report and Hands Free operations must be completed and then the system can be Disarmed.
In Disarmed Mode, the CANCEL (Green) Button will flash once every 4 seconds to indicate the SmartLink unit is
functioning normally.
NOTE: If the option “Cb” CANCEL BUTTON is Enabled then the SmartLink unit will Restore any outstanding alarms or
put the SmartLink unit to Disarmed Mode when the CANCEL (Green) Button is pressed.
8.2 ARM MODE
Press ON Button on a Radio Key Pendant (any programmed User Key with options “Sc” SECURITY, “Pn” PANIC, “dP”
DELAY PANIC or “du” DURESS) to ARM. The exit delay time is programmed in as an option “E1” EXIT TIME. During
exit delay time “A” for ARMED will be displayed.
Speaker will give one beep at the start of exit delay time. At the end of exit time the display extinguishes and the speaker
gives a single beep to indicate that the system is fully ARMED.
If the option “OC” OPEN/CLOSE REPORTS (Contact ID Version only) is Enabled then Open/Close reports are sent to the
Control Centre.
Tampers will cause the SmartLink unit to Alarm and will be reported to the Control Centre.
Rapid chirps for 4 seconds during EXIT DELAY TIME “E1” indicates a Reed Switch is unsealed. “A1” – “A8” will
indicate the unsealed Detector. Detector Trouble will be reported, if Reed Switch is still unsealed at the end of exit time.
NOTES:
• All Detectors in ARM and HOME Mode will alarm when system is in this mode.
• ARM mode may only be entered if at least one Detector is programmed with an option “Al” ALARM, “Ho” HOME or
“Si” SILENT. The SmartLink unit must be in DISARMED mode before entering ARM mode.
8.3 HOME MODE (Note: Contact ID Version Only)
Press ON Button 2 times on a Radio Key Pendant within 3 seconds to enter HOME mode (any programmed User Key with
options “Pn” PANIC, “dP” DELAY PANIC or “du” DURESS).
Speaker beeps 5 times and status display shows “H”. At the end of exit time the display extinguishes and the speaker gives
a single beep to indicate that the system is ARMED.
The CANCEL (Green) Button will flash once every 0.5 seconds to indicate the SmartLink unit is in HOME mode.
HOME mode has the same Entry and Exit Times as ARMED mode.
Rapid chirps for 4 seconds during EXIT DELAY TIME indicates a Reed Switch, that is programmed to “Ho” HOME
option, is unsealed. “A1” – “A8” will indicate the unsealed Detector. Detector Trouble will be reported if Reed Switch is
still unsealed at the end of exit time.