5.2.3 HARDWIRED INPUTS PROGRAMMING OPTIONS
Option Description
INPUT 1 PROGRAM (Default d = Disabled) - Reports to Channel 5
Disabled - Normally Open hardwired connection between Common and Inputs
Enabled – Initiates Emergency when Closed
(V2.3 Ademco onwards) Enabled – Initiates Emergency when Closed
(V2.3 Ademco onwards) Enabled – Initiates Call when Closed
1. “i1” is displayed on the SmartLink unit.
2. Press the HELP Button to view programmed option.
3. Pressing the HELP Button again toggles between d, E or d, E1 & E7.
4. To store an option selected, press the CANCEL and HELP Buttons at the same time. The SmartLink unit
will beep twice while flashing the display to acknowledge that the option has been selected.
5. Press the CANCEL Button to move to the next Program Option.
INPUT 2 PROGRAM (Default d = Disabled) - Reports to Channel 6
INPUT 3 PROGRAM (Default d = Disabled) - Reports to Channel 7
INPUT 4 PROGRAM (Default d = Disabled) - Reports to Channel 8
DEFAULT VALUES
– Sets all the Input Programming Options to Default Values
To Set all the Input Programming Options to Default Values:
1. “dF” is displayed on the SmartLink unit.
2. Press the HELP Button. The SmartLink unit will beep twice while flashing the display “- ” to indicate
that ALL Inputs (Inputs i1 to i4) have been Disabled.
3. Press the CANCEL Button to move to the next Program Option.
5.2.4 AUXILIARY OUTPUTS PROGRAMMING OPTIONS
Option
Description
(Open Collector output to ground when activated)
AUXILIARY OUTPUT 1 PROGRAM – Output 1 (Default 0 = OFF)
OFF (Output Disabled)
Enabled Output for 1 to 9 minutes & if Alarm Restored then Output is switched Off
Toggles Output On when in Alarm & if Alarm Restored then Output is switched Off
1. “o1” is displayed on the SmartLink unit.
2. Press the HELP Button to view programmed option.
3. Pressing the HELP Button again to step through the digits.
4. To store an option selected, press the CANCEL and HELP Buttons at the same time. The SmartLink unit
will beep twice while flashing the display to acknowledge that the option has been selected.
5. Press the CANCEL Button to move to the next Program Option.
AUXILIARY OUTPUT 2 PROGRAM – Output 2 (Default O = OFF)
AUXILIARY OUTPUT 3 PROGRAM – Output 3 (Default O = OFF)
DEFAULT VALUES –
Sets all Output Programming Options to Default Values
To Set all the Output Programming Options to Default Values:
1. “dF” is displayed on the SmartLink unit.
2. Press the HELP Button. The SmartLink unit will beep twice while flashing the display “- ” to indicate
that ALL Outputs (Outputs o1 to o3) have been Disabled.