SSHC TSSHC-3NPSBFS-16A User Manual

Manual is about: Heating floor non programmable electronic thermostat

Summary of TSSHC-3NPSBFS-16A

  • Page 1

    Ins-tsshc-3npsbfs-16a-1209 for further information or to consult this guide on line, please visit our web site. “tsshc-3npsbfs-16a” heating floor non programmable electronic thermostat user’s guide www.Sshcinc.Com.

  • Page 2: Warning

    Ins-tsshc-3npsbfs-16a-1209 2 warning warning before installing and operating this product,the owner and/or installer must read, understand and follow these instructions and keep them handy for future reference. If these instructions are not fol- lowed, the warranty will be considered null and void a...

  • Page 3: 1. Description

    Ins-tsshc-3npsbfs-16a-1209 3 1. Description the tsshc-3npsbfs-16a non programmable electronic ther- mostat can be used to control enerjoy radiant ceiling pan- els or heating floors with electrical current − with a resistive load − ranging from 0 a to 16 a at 120/208/240 vac. It has an easy user inte...

  • Page 4: • Parts Supplied:

    Ins-tsshc-3npsbfs-16a-1209 4 installation work and electrical wiring must be done by qualified person(s) in accordance with all applica- ble state/country codes and standards. • parts supplied: • one (1) thermostat; • two (2) mounting screws; • four (4) solderless connectors suitable for copper wire...

  • Page 5

    Ins-tsshc-3npsbfs-16a-1209 5 3. Using a screwdriver, loosen the screw retaining the mount ing base and front part of the thermostat. Remove the front part of the thermostat from the mounting base by tilting it upward. 4. Align and secure the mounting base to the connection box using the two screws s...

  • Page 6

    Ins-tsshc-3npsbfs-16a-1209 6 connectors. Please note that thermostat wires do not have polarity, meaning that any wire can be connected to the other. Then, install the floor temperature sensor. Four-wire installation 6. Reinstall the front part of the thermostat on the mounting base and tighten the ...

  • Page 7: 3. Operation

    Ins-tsshc-3npsbfs-16a-1209 7 3. Operation first start-up at the first start-up, the thermostat is initially in the day and floor modes. The temperature is displayed in degrees cel sius and the standard factory set point adjustment is 77ºf (25ºc). The maximum floor temperature is limited to 82°f (28°...

  • Page 8: Temperature Set Points

    Ins-tsshc-3npsbfs-16a-1209 8 temperature set points the figures beside the word set indicate the temperature set points (both in floor and ambient modes). They can be dis- played in degrees celsius or fahrenheit (see “display in degrees celsius/fahrenheit”). Out of any adjustment mode, press down th...

  • Page 9: Day Mode And Night Mode

    Ins-tsshc-3npsbfs-16a-1209 9 day mode and night mode the thermostat includes a day mode (sun) and a night mode (moon), both of them having their own independently adjust- able and recorded set point. When switching from one mode to the other, the system will automatically use the tempera- ture set p...

  • Page 10

    Ins-tsshc-3npsbfs-16a-1209 10 night mode timer adjustment procedure 1. First, switch to the night mode by simultaneously press ing down the + and - buttons and releasing them imme diately. 2. From the night mode, simultaneously press down the + and - buttons for more than 3 seconds until the icon se...

  • Page 11: Automatic Mode

    Ins-tsshc-3npsbfs-16a-1209 11 automatic mode the automatic mode, which is associated to the night mode timer, allows alternating between the day/night modes and the two corresponding set points over a 24-hour period. Once acti- vated, this mode allows an automatic return to the night mode after 24 h...

  • Page 12

    Ins-tsshc-3npsbfs-16a-1209 12 adjustment procedure of the automatic mode: 1. First, switch to the night mode by simultaneously press ing down the + and – buttons and releasing them imme diately. 2. From the night mode, simultaneously press down the + and – buttons for more than 3 seconds, until the ...

  • Page 13: Ambient/floor Mode

    Ins-tsshc-3npsbfs-16a-1209 13 display in degrees fahrenheit/celsius the thermostat can display the ambient temperature and the set point in degrees fahrenheit (standard factory setting) or celsius. Adjustment procedure for degrees fahrenheit/celsius dis play. 1. To switch from the degrees fahrenheit...

  • Page 14: Sensor Selection

    Ins-tsshc-3npsbfs-16a-1209 14 sensor selection if you want to use the tsshc-3npsbfs-16a thermostat of sshc, inc. With a temperature sensor already installed in the floor (other than the sensor supplied with this thermostat), you must con tact the sshc, inc. Customer service to validate the com patib...

  • Page 15: Backlighting

    Ins-tsshc-3npsbfs-16a-1209 15 backlighting the screen lights up when you press down a button. If you do not press down any button for more than 15 seconds, the screen turns off. N.B. If you press down the + or – button once when the back light is off, it will light up without changing the set point ...

  • Page 16: Lock Option

    Ins-tsshc-3npsbfs-16a-1209 16 lock option it is possible to impose a maximum temperature set point by ac- tivating this mode. Then, it becomes impossible to exceed this set point, regardless of the mode. However, it is still possible to lower the set point at your discretion. Please note that when t...

  • Page 17

    Ins-tsshc-3npsbfs-16a-1209 17 parameter backup and power failures the thermostat saves some parameters in its nonvolatile mem- ory in order to recovered them when power is restored (e.G. Af- ter a power failure). These are the four set points (day/ night/ ambient/floor), the automatic mode, the lock...

  • Page 18: 4. Troubleshooting

    Ins-tsshc-3npsbfs-16a-1209 18 4. Troubleshooting * e1: faulty ambient exterior sensor (open circuit) – written in the ambient section ** e2: faulty interior sensor (open circuit) – written in the ambient section *** e3: faulty floor sensor (open circuit) – written in the floor section n.B. If you do...

  • Page 19

    Ins-tsshc-3npsbfs-16a-1209 19 5. Technical specifications supply voltage: 120/208/240 vac, 50/60 hz maximum electrical current with a resistive load: 16 a 3840 w @ 240 vac 3475 w @ 208 vac 1920 w @ 120 vac range of temperature: 32 °f to 99°f (0 °c to 40°c) temperature display resolution: 1 °f (1 °c)...

  • Page 20: Limited Warranty

    Ins-tsshc-3npsbfs-16a-1209 20 limited warranty this unit has a 3 years warranty. If at any time during this period the unit becomes defective, return it to its place of purchase with a copy of the invoice, or contact our customer service department (with a copy of the invoice in hand). In order for ...