SSHC TSSHC-3NPSBFS-16A User Manual - Ambient/floor Mode
INS-TSSHC-3NPSBFS-16A-1209
13
Display in Degrees Fahrenheit/Celsius
The thermostat can display the ambient temperature and the set
point in degrees Fahrenheit (standard factory setting) or Celsius.
Adjustment procedure for degrees Fahrenheit/Celsius dis play.
1. To switch from the degrees Fahrenheit to the degrees Celsius,
and conversely, the thermostat must be from the Day mode. If
so, simultaneously press down the + and – buttons for more
than 3 seconds until the SET icon blinks.
2. Press down the + button to switch from the degrees
Fahrenheit to the degrees Celsius, and conversely. The
degree Fahrenheit or Celsius symbol is displayed.
3. When the adjustment is completed, do not press down any
button during 5 seconds to exit the adjustment function.
Ambient/Floor Mode
To switch from the Ambient mode to the Floor mode, or con-
versely, press down the A/F button (when you are not in any
adjustment mode). Then, the temperature set point will be-
come the same as the Floor or Ambient mode temperature, as
applicable.
Safe mode
If the thermostat fails to detect the presence of a floor sensor, it
will automatically revert to ambient mode at a setpoint of 70°F.
(with a maximum set point temperature of 75°F)