SSHC TSSHC-3NPSBFS-16A User Manual - Sensor Selection
INS-TSSHC-3NPSBFS-16A-1209
14
Sensor Selection
If you want to use the TSSHC-3NPSBFS-16A thermostat of
SSHC, inc. with a temperature sensor already installed in the
floor (other than the sensor supplied with this thermostat), you
must con tact the SSHC, inc. customer service to validate the
com patibility between the sensor and the thermostat. You must
know the serial number and name of the installed sensor.
Floor temperature offset
If the floor sensor is not correctly installed, the thermostat will
not indicate the right floor temperature (the indicated temper-
ature will be higher than the reality because the sensor is too
close to the heating cable). This feature allow to decrease the
measured temperature by 0°F to 18°F (0°C to 10°C) by incre-
ment of 1°C. To do so, you must:
1. Press down the A/F button for at least 30 seconds, the actual
value of this offset will be displayed in replacement of the
Floor mode set point and will blink. Then, you can release
the A/F button.
2. Press down the + button to increase this offset or – button to
decrease it. This offset will be displayed for 5 seconds.
N.B. This offset allow only to decrease the measured temperature
and not to increase it. The default value is 0°F (0°C).
Temperature Control
The thermostat controls the floor/ambient temperature (ac-
cording to the Ambient/Floor mode) with a high degree of ac-
curacy. When the heating starts or stops, it is normal to hear
a “clic” sound. It is the noise of the relay which opens or clos-
es, as applicable.