SSHC TSSHC-3NPSBFS-16A User Manual - page 12
INS-TSSHC-3NPSBFS-16A-1209
12
Adjustment procedure of the Automatic mode:
1. First, switch to the Night mode by simultaneously press ing
down the + and – buttons and releasing them imme diately.
2. From the Night mode, simultaneously press down the + and –
buttons for more than 3 seconds, until the icon SET starts to
blink, indicating that the adjustment of the Night mode timer
is effective. The figures that replace the ambi ent temperature
indicate the current timer adjustment. If needed, adjust the
timer by pressing down the + button to increase the value, or
the – button to decrease it. The Night mode timer adjustment
range is from 1 hour to 23 hours in the Automatic mode. To
quickly scroll through the timer values, press and hold down
the button.
N.B. If you set the timer to any value exceeding 23 hours, it will
be impossible to activate the Automatic mode and if it was
activated, the Automatic mode will be deacti vated.
3. Activate the Automatic mode by simultaneously pressing
down the + and – buttons for at least 3 seconds. The Au-
tomatic mode icon will appear. If the Automatic mode was
already activated, the same procedure should be used to
deactivate it.
4. When the adjustment is completed, release the buttons and
wait for 5 seconds to exit the adjustment function.
N.B. It is always possible to manually change the Day/Night mode
during a 24-hour cycle. In all cases, at the end of the 24-hour
cycle, the thermostat will return to the Night mode and start a
new cycle. It is thus not necessary to readjust the Automatic
mode when a manual change is made to the Day/Night
mode. If the thermostat is set OFF, the Automatic mode will
be deactivated.
When the power is restored after a power failure for example,
the Automatic mode is deactivated and its corresponding icon
is blinking. The icon will stop to blink as soon as you will press
down a button.