Vega VEGABAR 54 Product Information - page 21
Technical data
Process pressure/Hydrostatic – Pressure measurement
21
Supply voltage with lighted indicating and adjustment module
- Non-Ex instrument
13 … 32 V DC
- EEx-ia instrument
13 … 24 V DC
Power supply by/max. number of sensors
- H1 Fieldbus cable/Voltage supply
max. 32 (max. 10 with Ex)
Electrical protective measures
Protection
- Housing, standard
IP
66/IP 67
17)
- Aluminium and stainless housing (optionally available)
IP
66/IP 68 (1 bar)
18)
- Transmitter in IP 68 version
IP
68
- External housing
IP
65
Overvoltage category
III
Protection class
II
Existing approvals or approvals applied for
19
)20)
ATEX ia
ATEX II
1G, 1/2G, 2G EEx ia IIC T6
ATEX na
ATEX
3G EEx na II T5 … T1 X
ATEX D
ATEX II
1/2D, 2D IP6X T, ATEX II 1/2/-D, 2D IP6X T
FM(NI)
FM(NI) CL I, Div2, GP ABCD (DIP)CL II, III, DIV1, GP EFG
FM(IS)
FM(IS) CL I, II, III, DIV1, GP ABCDEF
CSA(NI)
CSA(NI) CL I, Div2, GP ABCD (DIP)CL II, III, DIV1, GP EFG
CSA (IS)
CSA (IS) CL I, II, III, DIV1, GP ABCDEFG
Ship approval
GL, LRS, ABS, CCS, RINA, DNV
Other approvals
VLAREM
CE conformity
EMC
2004/108/EG
EN
61326-1: 2006
LVD
2006/95/EG
EN
61010-1: 2001
Functional safety (SIL)
You can find detailled information in the supplementary instructions manual "Functional safety VEGABAR series 50 and 60" or under www.
vega.com.
Functional safety according to IEC 61508-4/61511
- Single channel architecture (1oo1D)
up to SIL2
- Double channel architecture (1oo2D)
up to SIL3
Environmental instructions
VEGA environment management system
certified according to DIN EN ISO 14001
You can find detailed information under www.vega.com.
17)
Instruments with gauge pressure measuring ranges cannot detect the ambient pressure when submerged, e.g. in water. This can lead to
falsification of the measured value.
18)
Only with instruments with absolute pressure ranges.
19)
Deviating data in Ex applications: see separate safety instructions.
20)
Depending on order specification.
29234
-EN
-081013