Summary of VEGABAR 81

  • Page 1

    Quick setup guide pressure transmitter with chemical seal vegabar 81 hart and accumulator pack document id: 46300

  • Page 2: Contents

    2 contents vegabar 81 • hart and accumulator pack 46300-en-160212 contents 1 for your safety 1.1 authorised personnel ....................................................................................................... 3 1.2 appropriate use ...........................................................

  • Page 3: 1  For Your Safety

    3 1 for your safety vegabar 81 • hart and accumulator pack 46300-en-160212 1 for your safety 1.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the ...

  • Page 4

    4 1 for your safety vegabar 81 • hart and accumulator pack 46300-en-160212 1.6 permissible process pressure the permissible process pressure is specified on the type label with "process pressure", see chapter " configuration ". For safety reasons, this range may not be exceeded. This applies even if...

  • Page 5: 2  Product Description

    5 2 product description vegabar 81 • hart and accumulator pack 46300-en-160212 2 product description 2.1 configuration the type label contains the most important data for identification and use of the instrument: 2 1 13 14 12 10 11 5 3 6 4 7 8 9 fig. 1: layout of the type label (example) 1 instrumen...

  • Page 6: 3 Mounting

    6 3 mounting vegabar 81 • hart and accumulator pack 46300-en-160212 3 mounting 3.1 general instructions for use of the instrument protect your instrument against moisture ingress through the following measures: • use the recommended cable (see chapter " connecting to power supply ") • tighten the ca...

  • Page 7

    7 3 mounting vegabar 81 • hart and accumulator pack 46300-en-160212 with the following instruments a blind plug is installed instead of the filter element: • instruments in protection ip 66/ip 68 (1 bar) - ventilation via capil - laries in non-detachable cable • instruments with absolute pressure.

  • Page 8

    8 4 connecting to power supply vegabar 81 • hart and accumulator pack 46300-en-160212 4 connecting to power supply 4.1 connection of the battery charger we recommended charging the integrated accumulator completely before setting up the instrument. You can find the charging time in chapter " technic...

  • Page 9

    9 4 connecting to power supply vegabar 81 • hart and accumulator pack 46300-en-160212 2 4 3 5 0 5 1 6 2 7 3 8 4 9 modes 4 on/off 3 on/off 1h 1,2 off charge accu 5..9 auto cycle 1 2 + ( ) (-) 1 fig. 5: supply room 1 internal connection of the socket for the battery charger 2 mode switch 3 led green, ...

  • Page 10: Module

    10 5 set up with the display and adjustment module vegabar 81 • hart and accumulator pack 46300-en-160212 5 set up with the display and adjustment module 5.1 insert display and adjustment module the display and adjustment module can be inserted into the sensor and removed again at any time. You can ...

  • Page 11

    11 5 set up with the display and adjustment module vegabar 81 • hart and accumulator pack 46300-en-160212 you can find " extended adjustment " in the next sub-chapter. 1. Measurement loop name in the first menu item you assign a suitable measurement loop name. Permitted are names with max. 19 charac...

  • Page 12

    12 5 set up with the display and adjustment module vegabar 81 • hart and accumulator pack 46300-en-160212 the quick setup is finished. 5.3 parameter adjustment - extended adjustment for technically demanding measuring points, you can carry out extended settings in " extended adjustment ". The main m...

  • Page 13

    13 5 set up with the display and adjustment module vegabar 81 • hart and accumulator pack 46300-en-160212 menu item parameter default setting application application level slave for elec- tronic differential pressure deactivated units unit of measure- ment mbar (with nominal measuring range ≤400 mba...

  • Page 14

    14 5 set up with the display and adjustment module vegabar 81 • hart and accumulator pack 46300-en-160212 menu item parameter default setting peak value pressure actual measured value temperature actual temperature values from meas- uring cell, electronics simulation pressure menu - additional adjus...

  • Page 15: 6 Supplement

    15 6 supplement vegabar 81 • hart and accumulator pack 46300-en-160212 6 supplement 6.1 technical data electromechanical data - version ip 66/ip 67 and ip 66/ip 68; 0.2 bar cable entry Ʋ m20 x 1.5 1 x cable gland m20 x 1.5 (cable: ø 6 … 12 mm), 1 x blind plug m20 x 1.5 Ʋ ½ npt 1 x blind plug npt, 1 ...

  • Page 16

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 46300-en-160212 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subjec...