Summary of VEGABAR 81

  • Page 1

    Quick setup guide pressure transmitter with chemical seal vegabar 81 profibus pa document id: 46302.

  • Page 2: Contents

    2 contents vegabar 81 • profibus pa 46302-en-160212 contents 1 for your safety 1.1 authorised personnel ....................................................................................................... 3 1.2 appropriate use .........................................................................

  • Page 3: 1  For Your Safety

    3 1 for your safety vegabar 81 • profibus pa 46302-en-160212 1 for your safety 1.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the req...

  • Page 4

    4 1 for your safety vegabar 81 • profibus pa 46302-en-160212 1.6 permissible process pressure the permissible process pressure is specified on the type label with "process pressure", see chapter "configuration". For safety reasons, this range may not be exceeded. This applies even if a measuring cel...

  • Page 5: 2  Product Description

    5 2 product description vegabar 81 • profibus pa 46302-en-160212 2 product description 2.1 configuration the type label contains the most important data for identification and use of the instrument: 2 1 13 14 12 10 11 5 3 6 4 7 8 9 fig. 1: layout of the type label (example) 1 instrument type 2 produ...

  • Page 6: 3 Mounting

    6 3 mounting vegabar 81 • profibus pa 46302-en-160212 3 mounting 3.1 general instructions for use of the instrument protect your instrument against moisture ingress through the following measures: • use the recommended cable (see chapter "connecting to power supply") • tighten the cable gland • when...

  • Page 7

    7 3 mounting vegabar 81 • profibus pa 46302-en-160212 with the following instruments a blind plug is installed instead of the filter element: • instruments in protection ip 66/ip 68 (1 bar) - ventilation via capil- laries in non-detachable cable • instruments with absolute pressure.

  • Page 8

    8 4 connecting to the bus system vegabar 81 • profibus pa 46302-en-160212 4 connecting to the bus system 4.1 connecting the voltage supply and signal output are connected via the spring- loaded terminals in the housing. Connection to the display and adjustment module or to the interface adapter is c...

  • Page 9

    9 4 connecting to the bus system vegabar 81 • profibus pa 46302-en-160212 fig. 4: connection steps 5 and 6 - double chamber housing 6. Insert the wire ends into the terminals according to the wiring plan information: solid cores as well as flexible cores with wire end sleeves are insert- ed directly...

  • Page 10

    10 4 connecting to the bus system vegabar 81 • profibus pa 46302-en-160212 5 0 0 5 1 6 2 7 3 8 4 9 0 5 1 6 2 7 3 8 4 9 1 0 1 6 7 8 bus 2 3 4 5 1 2 + ( ) (-) 1 fig. 5: electronics and terminal compartment, single chamber housing 1 voltage supply, signal output 2 for display and adjustment module or i...

  • Page 11

    11 4 connecting to the bus system vegabar 81 • profibus pa 46302-en-160212 bus 5 1 2 + ( ) (-) 6 7 8 2 3 4 1 fig. 7: terminal compartment, double chamber housing 1 voltage supply, signal output 2 for display and adjustment module or interface adapter 3 for external display and adjustment unit 4 grou...

  • Page 12: Module

    12 5 set up with the display and adjustment module vegabar 81 • profibus pa 46302-en-160212 5 set up with the display and adjustment module 5.1 insert display and adjustment module the display and adjustment module can be inserted into the sensor and removed again at any time. You can choose any one...

  • Page 13

    13 5 set up with the display and adjustment module vegabar 81 • profibus pa 46302-en-160212 1 2 fig. 9: installing the display and adjustment module in the double chamber housing 1 in the electronics compartment 2 in the terminal compartment note: if you intend to retrofit the instrument with a disp...

  • Page 14

    14 5 set up with the display and adjustment module vegabar 81 • profibus pa 46302-en-160212 2. Measurement loop name in this menu item you assign a suitable measurement loop name. Permitted are names with a maximum of 19 characters. 3. Application in this menu item, you activate/deactivate the slave...

  • Page 15

    15 5 set up with the display and adjustment module vegabar 81 • profibus pa 46302-en-160212 the quick setup is finished. 5.3 parameter adjustment - extended adjustment for technically demanding measuring points, you can carry out extended settings in "extended adjustment". The main menu is divided i...

  • Page 16

    16 5 set up with the display and adjustment module vegabar 81 • profibus pa 46302-en-160212 menu item parameter default setting units unit of measure- ment mbar (with nominal measuring range ≤400 mbar) bar (with nominal measuring rang- es ≥1 bar) temperature unit °c position correc- tion 0.00 bar ad...

  • Page 17

    17 5 set up with the display and adjustment module vegabar 81 • profibus pa 46302-en-160212 menu - additional adjustments menu item parameter default setting pin 0000 date/time actual date/actual time reset - copy in- strument settings special pa- rameters no reset scaling scaling size volume in l s...

  • Page 18: 6 Supplement

    18 6 supplement vegabar 81 • profibus pa 46302-en-160212 6 supplement 6.1 technical data electromechanical data - version ip 66/ip 67 and ip 66/ip 68; 0.2 bar cable entry Ʋ m20 x 1.5 1 x cable gland m20 x 1.5 (cable: ø 6 … 12 mm), 1 x blind plug m20 x 1.5 Ʋ ½ npt 1 x blind plug npt, 1 x closing cap ...

  • Page 19

    19 notes vegabar 81 • profibus pa 46302-en-160212.

  • Page 20

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 46302-en-160212 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subjec...