Wegner Crane CFW500 series Applications Manual - page 10
Quick Parameter Reference, Faults and Alarms
Crane | 10
Parameter
Description
Adjustable Range
Factory
Setting
User
Setting
Properties Groups Page
P1031
Speed Reference 1
0.0 to 500.0 Hz
6.0 Hz
SPLC
31
P1032
Speed Reference 2
0.0 to 500.0 Hz
60.0 Hz
SPLC
31
P1033
Speed Reference 3
0.0 to 500.0 Hz
0.0 Hz
SPLC
32
P1034
Speed Reference 4
0.0 to 500.0 Hz
0.0 Hz
SPLC
32
P1035
Speed Reference 5
0.0 to 500.0 Hz
0.0 Hz
SPLC
33
P1036
Dwell Time at Speed Reference 1
0.00
to 650.00 s
0.50 s
SPLC
33
P1038
Current Threshold for Lightweight
Detection
0.0 to 200.0 A
10.0 A
SPLC
49
P1039
Speed Threshold for Lightweight Detection
Enabling
0.0 to 500.0 Hz
0.0 Hz
SPLC
49
P1041
Load Frequency Threshold to Release the
Brake
0.0 to 500.0 Hz
4.0 Hz
SPLC
51
P1043
Current Threshold to Release the Brake
0.0 to 200.0 A
0.0 A
SPLC
55
P1045
Torque Threshold Release the Brake
0.0 to 350.0 %
0.0 %
SPLC
56
P1046
Brake Response Time to Release
0.00 to 650.00 s
0.10 s
SPLC
56
P1047
Inhibition of the Brake Closing during a
Forward/Reverse Command Transition
0 = Disabled
1 = Enabled
0
SPLC
56
P1048
Brake Closing Frequency Threshold
0.5 to 500.0 Hz
2.5 Hz
SPLC
56
P1049
Delay Time for Brake Closing
0.00 to 650.00 s
0.00 s
SPLC
57
P1050
Time to Enable a new Command to
Brake Release
0.10
to 650.00 s
0.20 s
SPLC
57
P1052
Momentary Overload Current Threshold
0.0 to 200.0 A
20.0 A
SPLC
63
P1053
Momentary Overload Detection Delay Time 0.00 to 650.00 s
1.00 s
SPLC
63
P1054
Momentary Overload Alarm (A770) Delay
Time
0.00 to 650.00 s
0.50 s
SPLC
64
P1058
Number of Consecutive Alarms for
Improper Fault (F777)
0 to 10
3
SPLC
69
P1059
Period of Time for Improper Fault (F777)
0 to 65000 s
120 s
SPLC
69