Wegner Crane CFW500 series Applications Manual - page 29
Parameters Description
Crane | 29
P0105 – 1st/2nd Ramp Selection
Adjustable
6 = SoftPLC
Factory Setting: 6
Range:
Proprieties:
Access groups via HMI:
BASIC
Description:
This parameter defines the source of the command that will select between the 1st and the 2nd ramp, which is
only SoftPLC for the crane application.
NOTE!
Refer to the CFW500 programming manual for more information on the ramp parameters.
3.3 SPEED LIMITS
This parameter group allows the user to configure the motor speed limits.
P0133 – Minimum Speed Reference Limit
Adjustable
0.0 to 500.0 Hz
Factory Setting: 5.0 Hz
Range:
Proprieties:
Access groups via HMI:
BASIC
Description:
This parameter defines the minimum motor speed reference value when the inverter is enabled. It is the value
used when the limit switch “Hoisting/Forward/Reverse Slowdown” is activated.
P0134 – Maximum Speed Reference Limit
Adjustable
0.0 to 500.0 Hz
Factory Setting: 60.0 Hz
Range:
Proprieties:
Access groups via HMI:
BASIC
Description:
This parameter defines the maximum motor speed reference value when the inverter is enabled. It is the value
used when the crane is operating in the “Lightweight” mode.
NOTE!
Refer to the CFW500 programming manual for more information on the speed limit parameters.
3.4 DYNAMIC BRAKING
This parameter group allows the user to configure the braking resistor to be used for dynamic braking.
NOTE!
Refer to the CFW500 programming manual for more information on the dynamic braking parameters.