Parameters Description
Crane | 26
3 PARAMETERS DESCRIPTION
Next, the parameters of the crane application, for both the CFW500 frequency inverter and the SoftPLC, will be
presented.
NOTE!
The adjustable range of the CFW500 parameters has been customized for the crane application.
Refer to the CFW500 programming manual for more details on the parameters.
Symbols for the parameter properties:
RO
Read-only parameter
RW
Read and write parameter
CFG
Configuration parameter, value can be programmed only with motor stopped
Vector Available when a vector control mode is chosen
3.1 ORIGIN OF THE COMMANDS
This parameter group allows the user to configure the origin of the CFW500 frequency inverter commands. For
this application, the inverter control in LOCAL situation is done via HMI and in REMOTE situation via SoftPLC
function.
LOCAL Situation:
It allows the user to command the motor of crane driven by the CFW500 inverter disregarding the control logics.
REMOTE Situation:
It enables the crane vertical or horizontal motion control logics, according to the programming performed by the
user.
P0220 – LOCAL/REMOTE Selection Source
P0221 – Speed Reference Selection - LOCAL Situation
P0222 – Speed Reference Selection - REMOTE Situation
P0223 – Forward Reverse Selection - LOCAL Situation
P0226 – Forward Reverse Selection - REMOTE Situation
P0224 – Run/Stop Selection - LOCAL Situation
P0227 – Run/Stop Selection - REMOTE Situation
P0225 – JOG Selection - LOCAL Situation
P0228 – JOG Selection - REMOTE Situation
NOTE!
Refer to the CFW500 programming manual for more information on the command origin parameters.
Some parameter options have been removed from the configuration wizard.