Charcoal Oven Installation and Operation Manual
inStallation ClearanCeS
CLEARANCES TO CONSTRUCTION
FLOOR:
The Wood Stone Josper oven must be installed on a non-combustible floor that extends 36” to the front and 30”
to each side of the oven door.
SIDES:
18” to combustible materials
BACK:
6” to combustible materials
This oven must be installed under a Listed Type 1 exhaust hood, or one constructed in accordance with NFPA 96. The
hood must be installed and maintained in accordance with NFPA 96 and/or all relevant local and national codes.
iF ThiS oven iS noT PRoPeRly inSTAlled A FiRe mAy ReSUlT. To RedUce The RiSk oF FiRe, FolloW TheSe
inSTAllATion inSTRUcTionS. A mAjoR cAUSe oF oven RelATed FiReS iS FAilURe To mAinTAin ReqUiRed
cleARAnceS (AiR SPAceS) To comBUSTiBle mATeRiAlS. iT iS oF UTmoST imPoRTAnce ThAT ThiS oven Be
inSTAlled only in AccoRdAnce WiTh TheSe inSTRUcTionS.
!
WARning: do not pack required air space (clearance) with insulation or other materials.
When non-combustible building materials contact the body of the oven, the clearances to
combustibles are transferred to those non-combustibles.