XENO XNR44P User manual - page 48
User’s Manual | 46
Relay
Off / Relay Output to trigger other device.
Dwell Time
Set the recording period from the start of sensor input activation. During this period, the corresponding camera
video will record according to the frame and alarm (relay) output set. The recording stops and alarm output is
turned off when the dwell time has elapsed.
4.4.2 System Alarm
S.M.A.R.T. alarm is an alarm signal triggered when the HDD is about to be out of operation.
Connection Failure. Alarm is activated when camera is disconnected.
Recording failure. Alarm is triggered when NVR doesn’t record normally.
Fan Failure. Alarm is triggered when internal fan is stopped.
N
OTE
“Sensor” here means the alarm connected to the NVR, which is triggered by physical sensor input or
transmitted data from network camera sensor input
N
OTE
If the sensor does not operate properly, check the setting of the sensor type (N/O or N/C). The alarm might
not function if the actual connecting sensor type and the sensor type in the system setting are inconsistent.
N
OTE
There are tree options to choose from the notify of Camera Input Sensor – All, Beep and Cam pop-up.
“Beep”
means that beep sounds automatically when an alarm is triggered.
“Cam pop-up”
means that multi-screen live video mode will be switched automatically to single channel
mode, when an alarm is triggered. This single channel video will be the channel triggered by alarm.
“All”
means that using “Beep” and “Cam pop-up” simultaneously when an alarm is triggered.