Xerox VersaLink B405 User Manual - page 182
Environmental Specifications
Temperature
• Operating Temperature Range: 10–32°C (50–90°F)
• Optimal Temperature Range: 15–28°C (59–82°F)
Relative Humidity
• Operating Humidity Range: 10–85%
• Optimal Humidity Range: 20–70% relative humidity at 28°C (82°F)
Note
Under extreme environmental conditions, such as 10°C and 85% relative humidity, printing defects can
occur due to condensation inside the printer.
Elevation
For optimum performance, use the printer at elevations below 3100m (10,170ft.).
Electrical Specifications
Power Supply Voltage and Frequency
Current Required
Frequency
Power Supply Voltage
11 A
60 Hz +/-3 Hz
110–127 VAC +/-10%
(99–140 VAC)
6 A
50 Hz +/-3 Hz
220–240 VAC +/-10%
(198–264 VAC)
Power Consumption
• Sleep mode: 4 W or less
• Low Power mode: 15.5 W
• Standby: 60 W
• Continuous printing: 620 W
Xerox
®
VersaLink
®
B405 Multifunction Printer
A-6
User Guide
Specifications