Xpresskit DBALL Installation Manual - page 19
LED
Status
Description
Troubleshooting
Module Programming
Solid red
Module is powered and waiting for
programming to begin.
Verify your power lines (D2D or W2W).
Solid green for
3 seconds
Module has been successfully
programmed.
Normal operation.
Flashes orange
Two keys have been detected
(Key2Go, Ignition has been turn
ON and OFF twice).
Normal operation, waiting for final step of programming.
Flashes red twice
Bypass not detected after 5
seconds when the ignition is ON.
Check the bypass connection.
Flashes red 4 times
Internal error.
Contact technical support.
Active Ground While Running
Flashes green
Ground out (GWR) is active
The Ground While Running signal has been lost or never
been seen by the module. Refer to the wiring diagram to
make the right connections. If in D2D, make sure the
remote starter is engaging the remote start sequence.
Inactive Ground While Running
Flashes green twice
Unlock command has been
received.
If it does not flash, the bypass module did not receive the
signal. Verify the connections between the bypass and
the remote starter module.
Flashes green 3 times
Trunk command has been
received.
If it does not flash, the bypass module did not receive the
signal. Verify the connections between the bypass and
the remote starter module.
LED Diagnostics & Troubleshooting
Rev.: 20121128
Platform: DBALL
Firmware: FORD1
© 2012 Directed. All rights reserved.
Page 19
Solid
Solid x3 secs
Flashes
Flashes x2
Flashes x4
Flashes
Flashes x2
Flashes x3
4
5
Insert the key and turn it to the IGN position ON and OFF
two (2) times, LED will flash orange.
Unplug module and reconnect to xpresskit.com and follow
Key2Go instructions (bottom right).
&
Key at IGN
O
F
F
START
IG
N
6
Once completed, plug module back into vehicle. LED will be
solid green 3 sec and go out.
&
Off
Solid
Flashes Orange