To enter feature programming routine
-
Turn the ignition ON, then OFF.
-
Within 5 seconds, press and HOLD the programming button until the LED turns ON orange (after 3 seconds). Release the
Programming button.
-
The LED will flash green once slowly to indicate the feature number is 1. After a short delay, the LED flashes red rapidly to indicate
the current option of feature 1 (i.e. 1x green followed by 1x red indicates feature 1 is set to option 1). The flashing sequence will repeat
until a new command is entered.
Changing feature options
-
Press the lock/arm or unlock/disarm button on aftermarket transmitter to change the option of the selected feature.
-
The LED flashes red rapidly the number of times equal to the current option number. After a short delay, the LED flashes green slowly
the number of times to indicate the current feature. The flashing sequence will repeat until a new command is entered.
Accessing another feature
-
Press and release the programming button a number of times to advance from the current feature to the next desired feature.
-
The LED flashes green slowly the number of times equal to the feature number. After a short delay, the LED flashes red rapidly to
indicate the current option of the current feature. The flashing sequence will repeat until a new command is entered.
When the maximum number of features or options is reached, the LED will start flashing again from the first feature or option.
Once a feature is programmed
-
Other features can be programmed.
-
The feature programming can be exited.
Exiting feature programming
-
No activity for 30 seconds; after 30 seconds, the LED will turn ON orange for 2 seconds to confirm the end of the programming
sequence.
OR
-
Press and HOLD the programming button for 3 seconds. After 3 seconds, the LED will turn ON orange for 2 seconds to confirm the
end of the programming sequence.
Feature Programming
Programming
Button
Feature & Option List
It is recommended to configure all the features and options listed below using the configuration tool found on the module
flashing page on www.directechs.com. The web offers more options; however, manual configuration of the features is
possible using the information on this page.
* Default
Feat.
Operation
Flashes / Option
Description
1. No RF Output*
Module is connected to a remote starter using a standard installation.
2. RFTD Output
Module is connected to an XL202 using an RSR or RXT installation (when available).
3. SmartStart
Module is connected to SmartStart using an RSR or RXT installation (when available).
1. Driver priority*
Unlocks only the driver door when the button is first pressed, and unlocks all doors when it is
pressed a second time within 5 seconds.
2. All
Unlocks all doors when the button is first pressed.
1. Disabled
The OEM alarm will not be controlled by the interface upon remote start. No disarm or arm
command will be executed at the beginning or end of the sequence; it must be controlled by
the Remote Starter.
2. Safelock
Smart OEM Alarm Control will behave like a standard Safelock feature on a remote starter. It
will unlock at the beginning of the sequence, and relock after start and shutdown.
3. Enabled*
Smart OEM Alarm Control will synchronize with the OEM alarm so that it will disarm and
rearm the vehicle in the remote start sequence, only when required. Smart OEM Alarm Control
will monitor the alarm and door lock status to detect if the disarm or rearm is required. If the
vehicle is unlocked or is not equipped with factory alarm, the disarm/rearm will not be
executed.
1
RFTD Output
Type
2
Unlock Driver
Priority
3
Smart OEM
Alarm Control
Rev.: 20171012
Platform: DBALL2
Firmware:
VW06