3D Systems ProX DMP320 User Manual - page 76
76
3D SYSTEMS, INC
.
Cleaning the Chiller Air Vent and Changing the Air Vent
Filter
If the fins of the air-condenser become clogged with dust or debris,
heat radiation performance reduces . This results in the reduction of
cooling performance, and may stop the operation because the safety
device is triggered .
1 . Shut off the power supply of the product when performing
cleaning, maintenance or inspection to avoid electric shock,
injury or burn, etc .
2 . Use a long bristled brush or air gun to clean the condenser to
prevent the fins from being deformed or damaged.
3 . To replace the filter, remove the filter panel and replace with
“SMC Filter Element AF/AW30 (Scott Equipment #AF30P-060S)”
(p/n 132576-00) .
4 . Refer to the OEM documentation for detailed instructions .
Drain Filter Replacement
When the chiller is free of fluids, open the drain filter housing at the
rear of the chiller and uninstall/reinstall a Pentek CW-F Polypropylene
Wound Filter (Scott Equipment #155186-43).