Summary of MS2830A

  • Page 1

    Configuration guide ms2830a signal analyzer configuration guide.

  • Page 2: Ms2830A Signal Analyzer

    2 configuration guide l ms2830a this explains how to order the new ms2830a and ms2830a retrofit options and measurement software. Follow the steps below to select the ms2830a configuration. Functions marked “standard” are built-in. Options and measurement software can be added as necessary. Steps fo...

  • Page 3

    Configuration guide l ms2830a 3 step 5. Add microwave preselector bypass (option) outline option no. Additional information microwave preselector bypass ms2830a-067 bypassing the preselector used for the microwave band improves rf frequency characteristics and in-band frequency characteristics. Supp...

  • Page 4

    4 configuration guide l ms2830a required options (analysis bandwidth) name model/order no. Analysis bandwidth extension option ( : required, +: function expansion, space (no symbol): no specification) opt. 006 opt. 005/009 opt. 077 opt. 078 mobile wimax measurement software mx269010a w-cdma/hspa do...

  • Page 5

    Configuration guide l ms2830a 5 step 8. Add other measurement software (these software are for pc. ) outline option no. Additional information wi-sun phy measurement software mx705010a supports automatic measurement of smart utility network wireless communications “wi-sun” phy conformance test cases...

  • Page 6

    6 configuration guide l ms2830a step 10-2. Add vector waveform generation tool (iqproducer) license (requires ms2830a-020 or ms2830a-021) outline option no. Additional information hsdpa/hsupa iqproducer mx269901a outputs waveform pattern created by setting hsdpa/hsupa uplink/downlink parameter with ...

  • Page 7: Retrofit to Current Ms2830A

    Configuration guide l ms2830a 7 hardware option retrofit the following hardware options can be retrofitted. Order the z1345a installation kit as well. The ms2830a must be returned to the anritsu plant for hardware retrofitting. Model/order no. Name reference steps hardware options ms2830a-101 rubidi...

  • Page 8

    8 configuration guide l ms2830a software option retrofit the following software options can be retrofitted. Order the z1345a installation kit as well. The ms2830a does not require return to the anritsu plant for software retrofitting. Model/order no. Name reference steps measurement software mx26901...

  • Page 9: Options Configuration Guide

    Configuration guide l ms2830a 9 options configuration guide options configuration refer two table shown below about the hardware / software which each frequency model of ms2830a can implement. Hardware frequency range (ms2830a-040/041/043/044/045) not upgradable. = can be installed, no = cannot be i...

  • Page 10

    10 configuration guide l ms2830a software = can be installed, no = cannot be installed, r = require, u = upgrade model name addition to main frame analysis bandwidth note 040 041 043 044 045 005 006 009 077 078 mx269010a mobile wimax measurement software no r r no mx269011a w-cdma/hspa downlink meas...

  • Page 11: Ordering Information

    Configuration guide l ms2830a 11 please specify the model/order number, name and quantity when ordering. The names listed in the chart below are order names. The actual name of the item may differ from the order name. Ordering information model/order no name ms2830a – main frame – signal analyzer p0...

  • Page 12

    • united states anritsu company 1155 east collins blvd., suite 100, richardson, tx 75081, u.S.A. Toll free: 1-800-267-4878 phone: +1-972-644-1777 fax: +1-972-671-1877 • canada anritsu electronics ltd. 700 silver seven road, suite 120, kanata, ontario k2v 1c3, canada phone: +1-613-591-2003 fax: +1-61...