Anton/Bauer Interactive 2000 PowerCharger Owner's Manual - page 4
FEATURES
1. Microprocessor Fuel Computer - Accurately monitors the energy
in the battery with programs that take into account battery age,
self discharge, charge/discharge rate, operating conditions and
previously experienced charge/discharge cycles. The DIONIC
®
90 battery constantly “learns” its precise state of charge and
remaining capacity. This data is automatically transmitted to an
InterActive
®
charger.
2. Integral RealTime
®
‘LCD’ – This new and exclusive Anton/Bauer
feature displays both the remaining runtime and the percentage of
remaining battery capacity at all times - simultaneously. No special
adapters or set up is required. (see complete explanation page 3)
3. Viewfinder Fuel Gauge Display - Cameras which include the An-
ton/Bauer InterActive viewfinder feature connect with the DIONIC
®
90 battery “Fuel Computer” to display an accurate “Fuel Gauge”
of remaining battery capacity in the viewfinder. Reference your
camera/camcorders owner’s manual for proper menu settings.
4. Impac
®
Case design - High impact case construction protects
the cells from impact that would damage or destroy conventional
batteries.
5. Gold Mount
®
Interface - Patented worldwide standard Gold
Mount connector is compatible with all Anton/Bauer camera
mounts and accessories.
6. Individual Computer Testing – As with all Anton/Bauer batter-
ies, each and every InterActive DIONIC
®
90 battery is individually
tested to assure optimum capacity, voltage and overall quality.
A serialized computer performance graph as confirmation of this
testing is enclosed.
•
DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY
CHARGER OTHER THAN THE ANTON/BAUER InterActive OR T
SERIES CHARGERS SPECIFIED IN THIS MANUAL.
•
Allow the battery to reach a steady green (LifeSaver
®
) mode
before using for the first time. Please read the individual
charger Owner’s Manual to become acquainted with the
many unique operating features of the chargers.
•
The DIONIC
®
90 battery will be approximately 90% charged when
the LED’s on the charger indicate FLASHING GREEN. The battery
is 100% charged when the charger indicates STEADY GREEN.
The Dionic
®
90 battery may be removed from the charger and
discharged in either condition.
•
The Dionic
®
90 battery can remain on the charger until just
prior to being used. The LifeSaver (STEADY GREEN charger
LED indication) maintenance routine keeps the battery charged
and ready for use. If the battery will not be used for an extended
period (more than 60 days) see “Operating Guidelines” on page
4.
For best results this battery should be used or returned to the InterAc-
tive or T Series charger within 48 hours of being removed from the
charger.
Note:
On some older chargers it may be necessary to install battery
on charger, wait one (1) minute, then remove battery and re-install.
This procedure may need to be repeated more than once to “wake
up” a low voltage battery.
NOMINAL CHARGE TIMES FOR DIONIC 90
Charge Level LED Indicators
90% Flashing Green
100% Steady Green
DUAL 2722 (2 batteries simultaneously)
2hrs.
3hrs.
InterActive PowerCharger
(QUAD/DUAL – 2702/2701/2700)
(QUAD/DUAL – 2401/2400)
2 hrs.
3 hrs.
T2 (2 batteries simultaneously)
2hrs.
3hrs.
Tandem
®
70
2hrs.
3hrs.
TM4 (4 batteries simultaneously)
2hrs.
3hrs.
Twin (2 batteries simultaneously)
4hrs
5hrs.
TWQ (4 batteries simultaneously)
4hrs.
5hrs.
Charge time can vary depending on age, condition and remaining capacity of each battery at the time it is placed on the charger.
2
CHARGING DIONIC BATTERIES
Approved Copy