[Auto Close]
[Disabled] / [Enabled]
The fi rst automatic-closing wait starts when the opening endstop point is reached and can be set to between 0 and 300 s. The automatic closing
does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power outage.
[Maint Action]
[Disabled] / [Enabled] / [Closing]
The gate leaves close by keeping a button pressed. Opening button on contact 2-3 and closing button on contact 2-4. All other control devices,
even radio-based ones, are excluded.
[Obstruc Detct]
[Disabled] / [Enabled]
With the gate-leaves closed, open or after a total stop, the operator stays idle if the safety devices (photocells and sensitive safety-edges) detect
an obstruction.
[Safety Test]
[Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ]
After every opening or closing command, the board will check whether the photocells are working properly
.
[Prefl ashing]
[Disabled] / [Enabled]
After an opening or closing command, the fl ashing connected onto W-E fl ashes before starting the maneuver.
To set the time, see
[Preflashing T]
in the
[ADJUST TIMES] menu
.
[Ram Jolt]
[Disabled] / [Closing] / [Opening] / [Open-Close]
Before any opening and closing maneuver, the gate leaves thrust inward to help release the electro-lock. To adjust this thrust time, select
[Ram
hit time]
in the
[ADJUST TIMES] menu
.
[Total Stop]
[Enabled] / [Disabled]
NC input - Gate-leaves stop with automatic closing excluded; to resume movement, use the control device. The safety device is inserted into 1-2.
[CX input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
[CY input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
[CZ input]
[Disabled] / [C1] / [C2] / [C3] / [C4] / [C7] / [C8]
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
[Closing thrust]
[Disabled] / [Enabled]
When the run reaches the endstop, the operator performs a closing thrust for a some seconds.
[Lock]
[Disabled] / [Closing] / [Opening] / [Open-Close]
Set the electric lock, to lock the leaves,
on any function chosen among those available
.
[Confi g]
[Slow Down] / [Op LS-Cl Sl Dn] / [ENCODER] / [Time Lmt Swtch] / [End Stop]
Configuring the opening and closing slow-downs
[Slow Down]*
[Op LS-Cl Sl Dn]*
[ENCODER] menu
[Time Lmt Swtch]
[End Stop]
➡ opening and closing slow-downs.
➡ opening endstop and closing slow-down.
➡ slow-down management, obstruction detection and sensitivity.
➡ timed endstop.
➡ opening and closing endstop.
*
slowdowns configurable with the [Slow down time] in the [SET TIMES]
[End stop]
[N.C] / [N.O]
Configuring the endstops as normally opened or closed contacts.
This function only appears if option is selected between
[End stop]
,
[
Op LS-Cl Sl Dn
]
or
[
Slow Down
]
from the [Confi g] function
.
[2-7 command]
[Open-Close] / [Opn Stp Clse]
Configuration
contact 2-7 in step-step (open-close) or sequential (open-stop-close-stop).
[2-3P command]
[Pedestrian] / [Partial]
Configuring contact 2-3P to pedestrian opening (total opening of the second gate-leaf) or partial (partial opening of the second gate leaf)
depending on the time set on [Partial open] in the [SET TIMES] menu.
[FUNCTIONS]
Functions menu