ENCODER menu
[ENCODER] menu
[Sensitivity]
[Enabled] / [Disabled]
Obstruction detection sensibility.
[Travel sens]
[-
+]
Obstruction detection sensitivity during gate run (both opening and closing).
You need to turn on the [Sensitivity] in the [ENCODER] menu.
[Slw Dwn sens]
[-
+]
Obstruction detection sensitivity during slow-down (both opening and closing).
You need to turn on the [Sensitivity] in the [ENCODER] menu.
[Enc Slow Down]
[ON] / [OFF]
Activating the opening and closing slow-down starting points.
[M1 Opn Slw Dwn]
[1%]
⇨
[60%]
Adjusting M1's slow-down starting point before the opening endstop.
The slow-down starting point is calculated as a percentage (from 1% to 60% of the complete gate-leaf run).
This function only appears if the [Enc Slow Down] in the [ENCODER] menu.
[M1 Cls Slw Dwn]
[1%]
⇨
[60%]
Adjusting M1's slow-down starting point before the closing endstop.
The slow-down starting point is calculated as a percentage (from 1% to 60% of the complete gate-leaf run).
This function only appears if the [Enc Slow Down] in the [ENCODER] menu.
The [ENCODER] menu appears only when the [Config] is selected in the [FUNCTIONS] menu.
[E Light]
[Courtesy] / [Cycle]
Configuring the light connected to 10-E:
- courtesy: freely positionable outdoor light, for increasing lighting in driveway/parking area. It stays on for a preset five minutes;
- cycle: freely positionable outdoor light for increasing lighting in the driveway/parking area. It stays lit from the moment that the gate leaf starts
opening until it is completely closed (including the automatic closing time). In case the automatic closing in not inserted, it stays on only during the
movement.
[B1-B2 output]
[Monostable] / [Bistable]
Configuring contact B1-B2 in Monostable or Bistable mode (switch).
[Slow dwn speed]
[-
◦+]
Setting the opening or closing or only closing slow-down speed if the slow-down is configured as [Op LS-Cl Sl Dn].
[No. of motors]
[M1+M2] / [M2]
Setting the number of motors from one to two depending on how many gate-leaves the system has.
[Motor type]
[FROG] / [AXO] / [FAST] / [FERNI] / [FROG PLUS]
Setting the type of operator for the swing gates on the system.
[Sleep mode]
[Disabled] / [Enabled]
For the photocells to reduce energy consumption when in stand-by mode ( with GP1 module connected).
[CRP address]
[1]
⇨
[32]
With systems fitted with several operators and the CRP (Came Remote Protocol) system connection, set an address between 1 and 32 for each
control panel.
[CRP baudrate]
[1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200]
Setting the communication speed used in the CRP (Came Remote Protocol) connection system.